![EuroTel ETL0480TBD Technical Manual Download Page 27](http://html.mh-extra.com/html/eurotel/etl0480tbd/etl0480tbd_technical-manual_2440481027.webp)
EUROTEL - ITALY
ETL0480TBD
WARNING LED also turns off when this memory is cleared.
-
Shows the previous warning condition.
+
Shows the next warning condition.
View Work Timer
Shows the working time of the amplifier in hours
TX enable config
Extern Enabled
Amplifier externally enabled. An external signal coming from the Exciter is needed for turn-on.
Always Enabled
Amplifier always enabled. The Amplifier switches on as soon as A.C. power is switched on and the
automatic EEPROM test has been carried out by the internal microprocessor.
ALC ref. power
Changes the reference power of the A.L.C. loop and is used to set the RF power output.
Store
Stores the new reference power level.
-
Decreases the reference power level.
+
Increases the reference power level.
TX A.L.C. config
Enables o disables the A.L.C. loop. When the loop is disabled, the display shows: “A.L.C. contr. off”.
ALC Disabled
The A.L.C. control loop is disabled.
ALC Enabled
The A.L.C. control loop is enabled.
ALC on AUX input
The A.L.C. control loop is enabled, the reference power is referred to the power read on external
aux. Input.
Store LCD View
The measures on the two rows of the display now, will be displayed at power on of the amplifier.
Second level menu
MENU
DESCRIPTION
Vision Frequency
Set approximately the frequency of the Vision carrier at witch the amplifier is working, in order to
provide course correction of the frequency amplitude response of the directional couplers.
Store
Set the new working Vision Frequency.
-
Decreases the working Vision Frequency.
+
Increases the working Vision Frequency.
Page 26 CMAN0480ENG
October
2002