EUROTEL - ITALY
ETL0480TBD
Figura 5 A.C. Mains distribution module – rear panel
•
Prime power line connection:
Connect the ground rod terminal to ground and the R S and T terminal to the three phases.
•
The ETL480TBD RF Amplifier is cooled by forced air stream entering from each front panel
opening of the RF ETL0470 amplifiers. The air is sucked in by one blower installed in the rear of
the rack cabinet. The hot exhaust air is again sucked by another blower installed on the top of the
rack cabinet.
•
The air can be ducted externally by means of flexible, lightweight tubing, with a diameter of 350
mm. The maximum allowable ducting length is 5 meters. With longer runs, a suitable depression
must be created by means of an external fan.
2 ) Other connections
•
Both the ETL0470 make available external alarm connections by means of hard wired and
insulated relay contacts. Additionally, all significant operating parameters are provided on a
standard RS-232 or RS-485 interface.
•
To wire the relay contacts to external circuits, see sub-chapter 10 following and use the ALARMS
OUT socket. Note that contacts are rated 48 V D.C. @ 0.1A maximum.
Page 16 CMAN0480ENG
October
2002