Eurotech ReliaGATE 10-20 User Manual Download Page 9

ReliaGATE 10-20 User Manual 

Safety and Regulatory  

110129-00011 

 

To avoid any possible legal implications contact your local waste collection body for full recycling 
information. 

 

 

RoHS  

This device, including all the components, subassemblies and the consumable materials that are an integral part 
of the product, have been manufactured in compliance with the European directive 2002/95/EC known as the 
RoHS directive (Restrictions of the use of certain Hazardous Substances). This directive targets the reduction of 
certain hazardous substances previously used in electrical and electronic equipment (EEE). 

EMC Requirements for Industry Canada 

 

This Class B digital apparatus meets all requirements of the Canadian Interference

Causing Equipment Regulations.  This device complies with Industry Canada RSS 
Appliance radio exempt from licensing.   The operation is permitted for the 
following two conditions: 

1)

 

The device may not cause harmful interference, and 

2)

 

The user of the device must accept any interference suffered, even if the 
interference is likely to jeopardize the operation. 

 

      

FCC Part 15 Class B Statement 

 

This equipment has been tested and found to comply with the limits for a Class B 
digital device, pursuant to part 15 of the FCC Rules. These limits are designed to 
provide reasonable protection against harmful interference in a residential 
installation. This equipment generates, uses, and can radiate radio frequency 
energy and, if not installed and used in accordance with the instructions, may 
cause harmful interference to radio communications. 

 

 

Warning:

 Changes or modifications to this unit not expressly approved by the party responsible for compliance 

could void the user’s authority to operate the equipment. 

Technical assistance 

For any technical questions, or if you cannot isolate a problem with your device, or for any enquiry about repair 
and returns policies, feel free to contact your local Eurotech Technical Support Team

.

 

See the back cover for full contact details. 
 
 

 

Summary of Contents for ReliaGATE 10-20

Page 1: ...ReliaGATE 10 20 Multi Service Gateway and Edge Controller USER MANUAL Revision 1 October 2014 110129 00011...

Page 2: ...Eurotech Trademarks All trademarks both marked and unmarked appearing in this document are the property of their respective owners Revision history Revision Description Date 1 Initial release October...

Page 3: ...2 Table of Contents 3 Safety and Regulatory 4 Overview 11 Block Diagram 12 Features 13 Product Options 14 Related Documents 14 Interfaces 15 Power 17 Communications 18 User Interface 22 Discrete I O...

Page 4: ...ained herein Eurotech reserves the right to revise this document or to make changes to its content at any time without any obligation to notify any person of such revision or changes Alerts that can b...

Page 5: ...definite safety hazard Antistatic precautions WARNING To avoid ESD Electro Static Discharge damage always use appropriate antistatic precautions when handing any electronic equipment Connection to pow...

Page 6: ...use any potentially hazardous situations e g falling down due to vibration or shock Do not operate the device near heat sources or flames NOTE If the device must be moved from one place to another wit...

Page 7: ...ge of this manual for further details Cleaning WARNING When cleaning the device remember to Ensure sufficient ESD protection during the cleaning process Remove any power from the device When cleaning...

Page 8: ...below complies with the regulations set out in the 2002 96 EC directive subsequently superseded by 2003 108 EC It refers electrical and electronic equipment and the waste management of such products...

Page 9: ...itions 1 The device may not cause harmful interference and 2 The user of the device must accept any interference suffered even if the interference is likely to jeopardize the operation FCC Part 15 Cla...

Page 10: ...connecting the equipment into an outlet on a different electrical circuit Additional restrictions and requirements may be listed in the System Specifications Warning Any product returned to Eurotech...

Page 11: ...applications including GPS Wi Fi 2G 3G cellular and IEEE 802 15 4 ZigBee Standard and wired connectivity such as USB 2 0 Gigabit Ethernet serial ports CAN analog inputs and isolated digital I O With...

Page 12: ...s wireless modules Smart Power Controller Reset Vin Power Input IGN CPU OFF Alive USB ETH Audio CODEC ReliaGATE 10 20 ReliaCELL 10 20 USB 3 0 3 3V PCIe USB OTG LCD Micro HDMI HDMI SIM GPS SMA UART 5 U...

Page 13: ...rnet ports Three USB 2 0 host ports One CAN2 0 bus Wi Fi IEEE 802 11 GPS receiver Cellular Accepts ReliaCELL 10 20 modems Indicators Ten LED status indicators Discrete I Os Two analog inputs Four digi...

Page 14: ...these options contact your local Eurotech representative for availability Related Documents This manual describes the ReliaGATE 10 20 at the system level and is intended for installers software devel...

Page 15: ...munications user interface discrete I Os and power supply features of the ReliaGATE 10 20 The following images illustrate the location of the interface connectors Front Panel ReliaGATE interfaces expo...

Page 16: ...Interfaces ReliaGATE 10 20 User Manual 16 110129 00011 Rear Panel...

Page 17: ...rouded receptacle housing Molex Mini Fit 5557 series p n 39 01 2040 etc Crimp receptacle for 18 24 AWG wire tin plated 4 ea Molex p n 39 00 0039 or 39 00 0060 The ReliaGATE 10 20 power connector is a...

Page 18: ...eptacle Mating connector SMA cable with nut inside threads and center pin The ReliaGATE 10 20 includes a multi channel GPS receiver for accurate location information worldwide Connect an external GPS...

Page 19: ...ard until it clicks into place Press on the card again to eject it SIM Connector SIM socket push push type Mating connector SIM card from a cellular service provider If your model of the ReliaCELL 10...

Page 20: ...net Connector RJ 45 socket with chassis grounded shell Mating connector RJ 45 plug shielded cable optional and supported The ReliaGATE 10 20 provides two RJ 45 gigabit Ethernet ports on the rear panel...

Page 21: ...NC 1 RDX5 I 4 TXD5 O 6 NC 9 NC Serial 2 Connector DB 9 M header Mating connector DB 9 F cable This connector provides access to two serial ports Connect a standard EIA 232 cable to access four wire p...

Page 22: ...yellow On Board Cellular PWR green Controllable by the operating system Can indicate system status LED Group 2 ZIG GPS BT Group 2 LEDs lie next to the DB9 serial connectors and are organized as follo...

Page 23: ...1000 Mbps ON blink ON blink HDMI Display Connector Micro HDMI socket Mating connector Micro HDMI cable assembly The ReliaGATE 10 20 includes an HDMI display output This output requires licensing for...

Page 24: ...following figure shows the layout of the base strip Screw the mating wires into the pluggable terminal block plug the terminal block into the base strip and secure the terminal block to the base stri...

Page 25: ...nclosure consisting of a base plate with mounting tabs and lid This section provides mechanical details about the enclosure Mechanical Drawings The following mechanical drawings specify the dimensions...

Page 26: ...wer 7 12 to 24 37 V VRTC RTC backup battery note 2 2 8 3 V Notes 1 The enclosure on early ReliaGATE 10 20 models indicates a lower limit on the input voltage While the unit might run at that voltage i...

Page 27: ...capacity could be an issue the extended capability is to provide transient load support 5V regulator maxes out at 3A Symbol Parameter Min Typ Max Units VCC Output voltage 5 V IOUT Output current 1000...

Page 28: ...aiding data connection speed and latency 27 s 27 s 1 s 3 s Sensitivity demonstrated with a good active antenna Tracking Navigation Reacquisition for an outage duration 10 s Cold Start without aiding H...

Page 29: ...voltage VCC 5 V 2 VCC V VIL Low level input voltage VCC 5 V 0 0 8 V Notes 4 Conversion rate is dependent on I2 C clock rates 5 Contact your Eurotech sales representative if the analog input in your a...

Page 30: ...support us eurotech com Web www eurotech inc com ASIA JAPAN ADVANET Tel 81 86 245 2861 Fax 81 86 245 2860 E mail sales advanet jp E mail tsupport advanet jp Web www advanet jp INDIA EUROTECH Tel 91 80...