15 Power supply. How to turn ON/OFF and reset the product
ReliaGATE 10-14 User manual Rev. 0-10
15.3
How to supply power and turn ON the product
WARNING
ELECTRIC SHOCK HAZARD
Failure to supply power correctly or to follow all operating instructions correctly, may create an
electric shock hazard, which could result in personal injury or loss of life, and / or damage the
equipment or other property.
To avoid injuries and safely supply power to the product, complete the following steps:
1. Observe all the instructions for safety, installation, and operation
2. Make sure your hands are dry
3. Make sure that all the cables to use:
a. Are in good condition
b. Meet the product requirements and comply with the relevant standards and
regulations
4. Position cables with care. Do not position cables in places where they may be trampled
or compressed
5. Make sure that the power-points and plugs are in good condition before using them
6. Do not overload the power-points and plugs
7. Make sure that the product maintains a proper grounding connection.
Always use the earth protection terminal to connect the ReliaGATE 10-14 to an earth
point in the installation: see also
"Earth connection terminal" on page 57
8. Use a power supply that meets the product requirements and complies with the relevant
standards and regulations. In case of uncertainties, contact the Eurotech Technical
Support Team (for more information see
"How to receive technical assistance" on
)
9. Connect power after the installation of the system has been completed
10. Never connect or disconnect the cables with the system or the external apparatus
switched ON.
Before supplying power to the product, complete the following steps:
1. Make sure that you have thoroughly reviewed all installation, operation, and safety
instructions
2. Make sure that the electrical installation is made correctly in compliance with the relevant
standards and regulations.
To supply power and turn ON the ReliaGATE 10-14, complete the following steps:
1. Setup a DC power source that:
o
Meets the ReliaGATE 10-14 power requirements
o
Delivers minimum power of 25W
2. Check the input voltage as close as possible to the Power IN connector. This is to compensate for
any cable losses, caused by cable length and other cable characteristics
3.
Make sure that the DC power source is turned OFF
4. Setup an external Type F fuse on the line coming from the negative terminal of the DC power
source (a 2A Type F fuse is appropriate for 24VDC operation)
5. Connect the DC power source terminals to the Power IN connector:
l
"Power IN +" to Pin 1
l
"Power IN -" to Pin 2
6. Turn ON the DC power source. The ReliaGATE 10-14 remains OFF
84 / 90
Summary of Contents for ReliaGATE 10-14 Series
Page 4: ...This page has been intentionally left blank...
Page 12: ...This page has been intentionally left blank...
Page 16: ...This page has been intentionally left blank...
Page 18: ...This page has been intentionally left blank...
Page 20: ...This page has been intentionally left blank...
Page 22: ...This page has been intentionally left blank...
Page 28: ...This page has been intentionally left blank...
Page 36: ...This page has been intentionally left blank...
Page 80: ...This page has been intentionally left blank...
Page 86: ...This page has been intentionally left blank...
Page 88: ...This page has been intentionally left blank...
Page 89: ...ReliaGATE 10 14 User manual Rev 0 10 Notes NOTES 89 90...