20
Installing the foam
gasket
Before inserting the appliance into the opening in the kitchen worktop, the supplied
foam gasket must be attached to the lower side cooking hob (see figure above).
Do not install the appliance without the foam gasket!
The gasket should be attached to the appliance in the following way:
- Remove the protective film from the gasket.
- Then, attach the gasket to the lower side approximately 2-3 millimetres from the
edge (as shown in the figure). The gasket must be attached along the entire length
and should not overlap at the corners.
Kitchen worktop cutoff
dimensions
• Only ovens fitted with a cooling fan may be installed underneath this cooking hob.
• Before installing an oven, the rear wall of the kitchen furniture element should be
removed in the area of the cooking hob cutout. Furthermore, a gap of at least 5 mm
should be left at the front side.
Installation procedure
(with springs)
• Worktop must be placed absolutely horizontal.
• Suitably protect the edges of the cut aperture.
• Connect the cooking hob to the mains power supply (see instructions for the
connection of the cooking hob to mains power supply).
• Put the supplied springs in their places.
• Insert the hob into the cut aperture.
• Press the hob firmly towards the worktop from above.
Installation procedure
(with fixing brackets)
The cooktop is fixed to the unit by means of the brackets and accessories provided.
Holes are provided in the bottom of the tray where you can attach the screws (C)
that hold the brackets (B) in place.
B
= fixing bracket
C
= screw
CONNECTING THE APPLIANCE TO THE POWER MAINS
• The appliance may only be connected by an authorized skilled technician.
• Electric system protection should comply with all relevant regulations.
• The connection clips can be accessed when the connection clip covers are
opened / removed.
• Before connecting the appliance, make sure the voltage indicated on the rating
plate is consistent with the voltage in your home circuit.
• The rating plate with basic information is attached on the lower side of the hob.
• The appliance is manufactured for use with the power supply voltage
220-240 V ~.
• In order to make a fixed connection to the mains, insert an all-pole circuit breaker
between the appliance and the mains. This device shall have a contact separation
in all poles, providing full disconnection under overvoltage category III conditions.
• Given the protection from the risk of fire, appliances of this type may be installed in