background image

(This page has been intentionally left blank)

Summary of Contents for DynaGATE 20-30 Series

Page 1: ...User manual DynaGATE 20 30 xx Automotive Multi service IoT Edge Gateway Intel Atom LTE Cat 4 6 Rev 0 7 29 March 2021 DYGATE 20 30_Man_ENG_0 7 ENGLISH...

Page 2: ...tions to operate as a coordinated whole in compliance with the applicable regulations Revision history Revision Description Date 0 5 Preliminary release Updated sections l 6 3 1 Intended use l 9 11 Di...

Page 3: ...s interfaces For more information see l Product overview on page 23 l Interfaces overview on page 37 l Interfaces in detail on page 41 3 Install the DynaGATE 20 30 For more information see l Mechanica...

Page 4: ...This page has been intentionally left blank...

Page 5: ...n s curit sur la connectivit sans fil 15 3 How to receive technical assistance 17 3 1 How to ask for technical support 17 3 2 How to send a product for repair 17 4 Comment obtenir une assistance techn...

Page 6: ...card 45 9 4 GNSS 46 9 4 1 GNSS features for versions 10 11 20 21 46 9 4 2 GNSS features for version 22 46 9 4 3 Antenna connector specifications 47 9 5 USB 0 USB 1 USB 2 48 9 5 1 USB 0 connector speci...

Page 7: ...echanical dimensions 65 12 How to install the product 67 12 1 Respect the clearance space 68 13 Power supply How to turn ON OFF and reset the product 69 13 1 Power supply specifications 69 13 2 Power...

Page 8: ...This page has been intentionally left blank...

Page 9: ...h Technical Support for more information see How to receive technical assistance on page 17 1 1 Warning messages 1 1 1 Warning messages for harm to persons To indicate an imminently hazardous situatio...

Page 10: ...s with care Do not position cables in places where they may be trampled or compressed 5 Make sure that the power points and plugs are in good condition before using them 6 Do not overload the power po...

Page 11: ...ennas used with the product must be installed with care avoiding any interference with other electronic devices and keeping a distance from persons greater than 20 cm If these requirements cannot be s...

Page 12: ...This page has been intentionally left blank...

Page 13: ...ment contacter le Support Technique d Eurotech pour plus d informations voir Comment obtenir une assistance technique page 19 2 1 Messages d avertissement 2 1 1 Messages d avertissement relatifs au do...

Page 14: ...e pas les placer dans des endroits o ils risquent d tre pi tin s ou comprim s 5 S assurer que les prises de courant et les connecteurs d alimentation sont en bon tat avant de les utiliser 6 Ne pas sur...

Page 15: ...NTION Les antennes utilis es avec le produit doivent tre install es avec soin en vitant toute interf rence avec d autres appareils lectroniques et au moins 20 cm des personnes Si ces exigences ne peuv...

Page 16: ...This page has been intentionally left blank...

Page 17: ...ny product returned to Eurotech that is found to be damaged due to inadequate packaging will not be covered by the warranty To send a product for repair complete the following steps 1 Go to the Eurote...

Page 18: ...This page has been intentionally left blank...

Page 19: ...urotech qui se trouve endommag en raison d un emballage inad quat ne sera pas couvert par la garantie Pour retourner un produit en Service Apr s Vente proc der comme suit 1 Se connecter au Support Eur...

Page 20: ...This page has been intentionally left blank...

Page 21: ...ir Negative signal Negative signal in differential pair 3 3 3 3 V signal level 5 5 V signal level NC No Connection Reserved Use is reserved to Eurotech 5 2 Conventions for signal types Convention Desc...

Page 22: ...This page has been intentionally left blank...

Page 23: ...luetooth Low Energy and a GPS with Untethered Dead Reckoning two mPCIe and one M 2 slots can be reconfigured to host custom expansions and peripherals Factory Option Sophisticated power saving and man...

Page 24: ...bottom side of the product Ref Label example Label content 1 l Product Number l Model Number l Serial Number l MAC ID Number l Eurotech logo l Manufacturer address l FCC ID and IC codes l Power supply...

Page 25: ...used indoors or in automotive applications l Be used with appropriate interconnecting and power cables l Be used with an external DC power supply source that o Meets the requirements stated on the id...

Page 26: ...0 Service Panel Serial 1x RS 485 RS 422 Isolated 1x RS 232 RS 485 RS 422 Isolated 1x TTL Console Service Panel CAN 2 0B 2x CANBus with 5V 100mA Power Out Isolated I Os 3x Isolated Digital Inputs 3x I...

Page 27: ...C Buttons 1x Reset 1x Programmable Service Panel SIM slot 2x nano SIM Push Push Service Panel User Configurable as Dual SIM Single modem or Single SIM Dual Modem POWER Input Nominal 12 24 VDC Range 6...

Page 28: ...ux SDK No Yocto based Eclipse Tooling Azul Java IoT Framework No Everyware Software Framework ESF Product versions 00 10 11 20 21 22 include Eurotech Everyware Linux Product versions 30 31 40 41 42 in...

Page 29: ...December 1994 on packaging and packaging waste 7 1 4 Product disposal and recycling This product at the end of its life cycle must be collected separately and managed in accordance with the provisions...

Page 30: ...could void the user s authority to operate this product 7 1 6 1 Class II product According to Commission Decision 2000 299 EC of 6 April 2000 establishing the initial classification of radio equipmen...

Page 31: ...0 Not Supported 56 5280 Not Supported 60 5300 Not Supported 64 5320 Not Supported 100 5500 Not Supported 104 5520 Not Supported 108 5540 Not Supported 112 5560 Not Supported 116 5580 Not Supported 120...

Page 32: ...C Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This product generates uses and can radiate radio frequency energy and if...

Page 33: ...Channel Number Frequency MHz North America FCC 36 5180 Indoor Usage Only 40 5200 Indoor Usage Only 44 5220 Indoor Usage Only 48 5240 Indoor Usage Only 52 5260 Not Supported 56 5280 Not Supported 60 5...

Page 34: ...e brouillage est susceptible d en compromettre le fonctionnement Le pr sent metteur radio a t approuv par Innovation Sciences et D veloppement conomique Canada pour fonctionner avec les types d antenn...

Page 35: ...de la FCC Cet appareil est conforme avec Sant Canada Code de s curit 6 Le programme d installation de cet appareil doit s assurer que les rayonnements RF n est pas mis au del de I exigence de Sant Can...

Page 36: ...e 2011 65 EU of the European Parliament and of the Council as regards the list of restricted substances 7 5 REACH compliance This product is assessed to be compliant with the regulation EC No 1907 200...

Page 37: ...485 RS 422 Default RS 232 Isolated Connector DB9 Male 8 CAN 0 CAN 0 CAN Specification 2 0 Parts A and B Connector DB9 Male 9 CAN 1 CAN 1 CAN Specification 2 0 Parts A and B Connector DB9 Male 10 Eart...

Page 38: ...view The Front Side Interfaces are as follows Figure 8 2 Front Side Interfaces layout Ref Description 1 LED indicators 2 Service Panel 3 Display Port 4 3x Isolated Digital Inputs 3x Isolated Digital O...

Page 39: ...terfaces layout Ref Description 1 Audio Connector 2 MicroSD card receptacle push push up to 32 GB MicroSD cards 3 MicroSIM care receptacle push push 4 USB 2 0 port USB2 5 Reserved 6 MicroSIM care rece...

Page 40: ...he LED Indicators are as follows Figure 8 4 LED Indicators layout Ref Description Color 1 User 1 Dual Color Green Amber 2 MiniPCIe Slot 3 Green 3 User 2 Dual Color Green Amber 4 MiniPCIe Slot 2 Green...

Page 41: ...GHz for Europe l 5 725 5 825 GHz FCC UNII high band for US Canada Bluetooth BT 4 0 BLE coexistence l 2402 2480MHz Data Transfer Rates WLAN 2 4 GHz l 11n Up to 150Mbps PHY dynamic l 11g Up to 54Mbps PH...

Page 42: ...Power 6 dBm RF receive Sensitivity Typical 802 11a 54M less than 74 dBm 802 11b 11M less than 89 dBm 802 11g 54M less than 75 dBm 802 11n 2 4G HT20 MCS7 less than 75 dBm 92 dBm at MCS0 HT40 MCS7 less...

Page 43: ...ps DL Max 50 Mbps UL LTE TDD Max 130 Mbps DL Max 30 Mbps UL UMTS DC HSDPA Max 42 Mbps DL HSUPA Max 5 76 Mbps UL WCDMA Max 384 Kbps DL Max 384 Kbps UL GSM EDGE Max 296 Kbps DL Max 236 8 Kbps UL GPRS Ma...

Page 44: ...commends the use of both CELL MAIN and CELL DIV antenna connectors If CELL DIV antenna is not used connected Eurotech recommends to disable the diversity function see 9 2 3 Antennas connectors specifi...

Page 45: ...eps 1 Orient the MicroSIM card with the contacts facing the circuit board and the cut corner highlighted with the letter A in the figure below facing the receptacle 2 Push the MicroSIM card and lock i...

Page 46: ...s AssistNow Autonomous up to 6 days OMA SUPL 3GPP compliant Oscillator Crystal Sensor Onboard accelerometer and gyroscope 9 4 2 GNSS features for version 22 Feature Description Receiver type 72 channe...

Page 47: ...nna connector specifications Connector Layout Connector Specifications l SMA connector l Gender Female Mating Connector Specifications l SMA connector l Gender Male Connector Pinout Pin Description 1...

Page 48: ...s l USB 3 0 Type A socket l Gender Female Mating Connector Specifications l USB 3 0 Type A plug l Gender Male Connector Pinout Pin Signal Type Description 1 VBUS 5 5V 2 D IO Data 3 D IO Data 4 GND P G...

Page 49: ...2 connector specifications Connector Layout Connector Specifications l USB Type A socket l Gender Female Mating Connector Specifications l USB Type A plug l Gender Male Connector Pinout Pin Signal Typ...

Page 50: ...oise and surge protected 9 6 2 ETH 0 and ETH 1 connectors specifications Connector Layout Connector Specifications l Panel mount M12 series l Gender Female l Type X Coded 8 pin Mating Connector Specif...

Page 51: ...nector Specifications l Standard 9 Pin D Sub plug l Gender Male Mating Connector Specifications l Standard 9 Pin D Sub socket l Gender Female Connector Pinout pins not listed are not connected Pin RS...

Page 52: ...ecifications Connector Layout Connector Specifications l Standard 9 Pin D Sub plug l Gender Male Mating Connector Specifications l Standard 9 Pin D Sub socket l Gender Female Connector Pinout pins not...

Page 53: ...i DisplayPort plug l Gender Male Connector Pinout Pin Signal Type Description 1 GND1 P Ground 2 HP O Hot Plug Detect 3 L0 O Lane 0 positive 4 CF1 O CONFIG1 5 L0 O Lane 0 negative 6 CF2 O CONFIG2 7 GND...

Page 54: ...tandard HD 15 Pin D Sub socket l Gender Female Connector Pinout Pin Signal Type Description 1 DOUT 1 P O Isolated Digital Output 1 2 DOUT 1 N O Isolated Digital Output 1 3 DOUT 2 P O Isolated Digital...

Page 55: ...electrical specifications of the digital inputs at 24VDC of nominal supply voltage Characteristic Value 24 VDC Logic Zero 0 V VIN_low 1 5 V Logic One 9 V VIN_high 36 V Minimum duration of the pulse 1...

Page 56: ...s The table below shows the electrical specifications of the digital outputs at 24VDC of nominal supply voltage Characteristic Value 24 VDC Maximum Current 250 mA Output ON Resistance Typical 0 85 Ohm...

Page 57: ...ons l Connector Housing l Gender Female l Type Pitch 1 25 mm 10 pin l Example Manufacturer Molex Part Number 51021 1000 or equivalent Connector Pinout Pin Signal Type Description 1 OUT_L O Left Line P...

Page 58: ...Low 0 to 0 8 V 9 13 1 TTL Serial Console connector specifications Connector Layout Connector Specifications l Shrouded header l Gender Male l Type Pitch 1 25 mm 3 pin Mating Connector Specifications l...

Page 59: ...GB for additional data storage 9 14 1 How to insert remove the MicroSD card in the receptacle To insert the MicroSD card complete the following steps 1 Orient the MicroSD card with the contacts facin...

Page 60: ...al signatures hashes that are extended into the PCR registers When a valid condition is matched a policy grants access to the NVRAM so that the bootloader can read the kernel public key The key read i...

Page 61: ...F is a high level multi platform and flexible application development environment for Edge Computers and IoT Gateways ESF connects and interfaces with field devices thanks to its ready to use field pr...

Page 62: ...reusable configurable components In the dataflow programming model the application logic is expressed as a directed graph flow where each node can have inputs outputs and independent processing units...

Page 63: ...access It also connects the data collected by field deployed devices to enterprise applications and analytics leveraging reliable and open protocols 10 5 For more information For more information and...

Page 64: ...This page has been intentionally left blank...

Page 65: ...ifications l Material Aluminium l Color Black Anodized 11 2 Product mechanical dimensions The product enclosure has the following dimensions 224 W x 128 D x 62 H mm connectors excluded All dimensions...

Page 66: ...This page has been intentionally left blank...

Page 67: ...omplete the following steps 1 See Mechanical specifications and dimensions on page 65 2 Use the 4 slots available on the enclosure 3 Add all the necessary mounting hardware to safely fasten the DynaGA...

Page 68: ...0 7 12 1 Respect the clearance space To ensure l proper air circulation around the product and l adequate space to install the product respect the clearance space indicated in orange in the following...

Page 69: ...pecifications The power input is protected against surge noise reverse polarity over voltage NOTICE The Power IN connector is NOT protected against short circuit Always include an external fuse to pro...

Page 70: ...2 8 Make sure that the product maintains a proper grounding connection 9 Use a power supply that meets the product requirements and complies with the relevant standards and regulations In case of unce...

Page 71: ...nnection terminal 7 Turn ON the DC power source The DynaGATE 20 30 remains OFF 8 Connect the KEY pin Ref B below to the positive DC power source terminal DC IN The DynaGATE 20 30 automatically turns O...

Page 72: ...sole 2 Enter the command poweroff The system turns OFF 3 Remove the power from the Power IN connector To turn OFF the DynaGATE 20 30 by turning OFF the Ignition Key complete the following steps 1 Turn...

Page 73: ...ies and safely remove power supply from the product complete the following steps 1 Make sure your hands are dry 2 Turn OFF all the power supply sources 3 Disconnect all the cables 4 Make sure that all...

Page 74: ...This page has been intentionally left blank...

Page 75: ...DynaGATE 20 30 User manual Rev 0 7 Notes NOTES 75 76...

Page 76: ...otech com For your Eurotech local contact refer to For the Eurotech Global Support Centre refer to For the Eurotech Download Area refer to eurotech com contacts support eurotech com eurotech com downl...

Reviews: