EUROSTER UNI4 

 USER MANUAL

 

1

 

EUROSTER UNI4

 

Weather-based heating system controller

 

 

MANUFACTURER: P.H.P.U. 

AS, Chumiętki 4, 63

-840 Krobia, Poland 

In order to take full advantage of the controller capabilities and ensure proper operation of the 
central heating system, please read this user manual carefully. 

Manual version: 01.02.2021

 

1. APPLICATION

 

UNI4 is a universal controller designed to control a heating system equipped with: 

 

Two independent CH zones with mixing valves (e.g. for floor heating, radiator heating) 

 

DHW circuit 

 

DHW circulation circuit (time-based control) 

 

Heating source control  

 

Feeding the buffer which supplies other zones 

 

Ability  to  control  cooling  or  heating  zones  with  a  switch-over  between  heating  and 
cooling by an external contact. 

Heating system diagram

 

 

 

Summary of Contents for UNI4

Page 1: ...manual carefully Manual version 01 02 2021 1 APPLICATION UNI4 is a universal controller designed to control a heating system equipped with Two independent CH zones with mixing valves e g for floor hea...

Page 2: ...zone temperature sensor S5 CH2 zone temperature sensor R1 CH1 zone room thermostat R2 CH2 zone room thermostat P1 CH1 zone pump P2 CH2 zone pump P4 DHW circulation pump M1 230 V 3 point actuator of t...

Page 3: ...of a gas fired boiler or other heating devices with a voltage free output NO NC relay contacts Alarm output 230 V 50 Hz output Event log the controller stores 15 last alarms or irregular situations S...

Page 4: ...ation selecting between menu items up down next previous and a confirmation button located in the center of the knob which also clears the display of alarm warnings CAUTION When changing a setting the...

Page 5: ...cted days of the week DHW circulation circuit schedule With the use of schedule we may preset the time of DHW circulation circuit operation on selected days of the week Heating season Switching to the...

Page 6: ...ity to achieve thermal comfort regardless of external temperature The only requirement is to connect an outdoor temperature sensor After switching the weather compensation on temperatures of the CH zo...

Page 7: ...ection at 0 00 The proper cleansing consists in heating the DHW tank to the temperature of 70 C and flushing the pipes with hot water The disinfection icon active in the display may last for 2 hours m...

Page 8: ...proximate to alarm temperatures It is important to ensure a safe level of alarm temperature for each zone Pump starting temperature Above this temperature the pumps of CH 1 CH 2 zones and DHW circuit...

Page 9: ...uirements Do not install the controller in rooms of increased humidity protect it against water and other liquids The controller is designed to be mounted on a 35 mm DIN rail in a protective cabinet D...

Page 10: ...hermostat control may be switched on or off for each central heating zone It is only allowed to use thermostats with a voltage free normally open NO contact It is recommended to use Euroster devices T...

Page 11: ...EUROSTER UNI4 USER MANUAL 11 Connection diagram for the cooling mode...

Page 12: ...xceeds the required one CH circulation pump is switched on if heating is active and the mixer is not closed However if maintenance operation continuous operation was activated the pump operates withou...

Page 13: ...hen thermostat output is disconnected after reaching the preset temperature in rooms 5 7 Buffer Pump Output Feeding no 2 voltage type This output is used to control the buffer pump the pump of additio...

Page 14: ...nected inversely and whether it is not jammed 6 2 A selected zone is subject to overheating Check Whether the valve is not blocked Whether the mixer actuator is operating Whether the actuator cables a...

Page 15: ...the Directive 2006 66 EC of the European Parliament and the Council Such marking informs that the electrical and electronic equipment and batteries may not be disposed of together with other househol...

Page 16: ...on the day when the manufacturer received the claimed device 5 The device may be repaired exclusively by the manufacturer or by a party clearly authorized by the manufacturer 6 Warranty becomes void i...

Reviews: