EUROSTER 4020TXRX Installation And Operation Manual Download Page 8

EUROSTER 4020TXRX 

 INSTALLATION AND OPERATION MANUAL

 

8

 

 

15.

 

DIMENSIONS 

 

16.

 

TECHNICAL DATA 

Controlled device 

air-conditioning / heating systems 

Supply voltage 

3 V (2 pieces of AAA batteries) 

Thermostat output 

relay, voltage-free type, SPST (normally open) 

Maximum load 

5 A 230 V 50 Hz 

Temperature measurement range 

°C...+99°C

 

Temperature control range 

+5 

°C...+35

 

°C

 

Temperature control accuracy 

0.1°C

 

Temperature read-out accuracy 

0.1 

°C

 

Hysteresis range 

0.2 

°C... 10

 

°C with 0.1

 

°C step of the change 

or PWM mode 

Visual signalization 

backlit LCD 

Operating temperature 

+5 

°C...+45

 

°C

 

Storage temperature 

0°C...+50°C

 

Ingress protection rating 

IP20 

Color 

white/gray 

Installation method 

thermostat 

 stand / receiver 

 230 V 50 Hz 

plug socket 

Thermostat weight without batteries 

thermostat without batteries 

 120 g / 

Receiver 

 170 g 

Frequency of operation 

868 MHz 

Maximum power of transmission   

< 25 mW 

Warranty period 

2 years 

Thermostat class 

IV (PWM mode) 

Thermostat contribution to the seasonal 
energy efficiency of room heating 

2 % (PWM mode) 

17.

 

KIT CONTENTS 

 

Euroster 4020TXRX 

thermostat 

 

Euroster RX

 receiver 

 

2 pieces of alkaline AAA batteries 

 

Installation and Operation Manual with Warranty Certificate 

18.

 

SIMPLIFIED DECLARATION OF CONFORMITY 

P.H.P.U.  AS  AGNIESZKA  SZYMAŃSKA

-

KACZYŃSKA  hereby 

represents  that  the  type  of 

EUROSTER  4020TXRX  equipment  conforms  to  the  following  directives:  2014/35/EU  (LVD), 
2014/30/EU (EMC), 2014/53/EU (RED), 2011/65/EU (RoHS). 
The complete text of the Declaration of EU conformity is available at the following Internet 
address:  

www.euroster.pl 

 

 

Summary of Contents for 4020TXRX

Page 1: ...e of 5 C 35 C The thermostat is programmable in daily operating cycles 2 BASIC THERMOSTAT FUNCTIONS Does not require leading cable connections between the thermostat and the controlled device User fri...

Page 2: ...Prior to mounting or dismantling the set make sure that the heating cooling system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage there...

Page 3: ...rving the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base CAUTION Use only alkaline AAA batteries to power the thermostat Do...

Page 4: ...hand button Press the right hand button again select comfort or reduced temperature Use buttons to set the desired temperature value confirm with the central button In order to disable the function ho...

Page 5: ...ton Active interlock is indicated by displaying the icon The interlock is active after 10 minutes The interlock is disabled in the same way This function is not active by default Temperature sensor co...

Page 6: ...ermostat and each receiver has a unique number that distinguishes it from others It is not possible for any thermostat not paired with the particular receiver to interfere with the operation of anothe...

Page 7: ...ce for a strong range and once for sufficient range 13 2 No radio communication If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this conditi...

Page 8: ...stat stand receiver 230 V 50 Hz plug socket Thermostat weight without batteries thermostat without batteries 120 g Receiver 170 g Frequency of operation 868 MHz Maximum power of transmission 25 mW War...