EUROSTER 4020TXRX Installation And Operation Manual Download Page 6

EUROSTER 4020TXRX 

 INSTALLATION AND OPERATION MANUAL

 

6

 

 

 

Exit (ESC) 

Press the central button to make the thermostat exit the service mode. 

You may also exit the menu by pressing the left “

" button. 

9.

 

TEST MODE (tSt) 

In  the  test  mode,  you  may  check  the  main  parameters  of  the  thermostat.  To  enter  the  test 
mode press and hold the 

central and “ ” button for ap

proximately 2 seconds.  

The following tests are available: 

 

internal sensor temperature measurement 

 

external sensor temperature measurement - press the central button, 

 

relay test - 

press the lower “ ” button repeatedly to switch the relay on/off,

 

 

backlight test 

 

press the upper “ ” button repeatedly to switch the backlight on/off.

 

10.

 

SWITCHING THE THERMOSTAT OFF 

When  the  switch  is  moved,  the  thermostat  goes  into  frost  protection  mode.  The 

 icon 

appears on the display. Frost protection ensures that the heating is turned on only to prevent 
the temperature from 

dropping below 4°C.

 

11.

 

ERROR INDICATION 

OP 

 sensor missing or damaged 

SH 

 short-circuit of a sensor or a damaged sensor 

Err 1 

 internal error

 remove and after a few moments reinstall the batteries. 

 

 discharged batteries icon. 

Err

 and   symbol 

 no radio communication. 

12.

 

RX RECEIVER SETTINGS 

12.1.

 

Establishing  a  connection  between  4020TX  thermostat  and  RX  receiver  or 

receivers (pairing) 

Each thermostat and each receiver has a unique number that distinguishes it from others. It is 
not  possible  for  any  thermostat  not  paired  with  the  particular  receiver  to  interfere  with  the 
operation of another pair or set. 
The  thermostat  may  be  paired  with  other  receivers  at  any  time.  A  blackout,  battery 
replacement as well as a complete reset of all thermostat settings do not affect the pairing of 
devices in any way. 
Pairing procedure: 

 

Enter the configuration mode in the thermostat  

 

Select the pairing mode (P)  

 

Press the central button 

 the display shows 0 

 

Insert the receiver into the plug socket  

 

Press the button on the receiver 3 times 

 the blue LED lights up 

 

When the receiver is detected, the display shows OK and the digit 1 (first receiver) 

 

If  you  are  using  only  one  receiver,  press  the  central  button  and  exit  the  menu.  The 
pairing mode is ended. 

If you are going to pair multiple receivers (maximum 6), proceed as follows: 

 

When the first receiver is detected (digit 1 on the display), 

 

insert the second receiver into the plug socket. 

 

Press the button on the receiver 3 times 

 the blue LED lights up. 

 

When the receiver is detected, the display shows 2 (second receiver). 

 

Proceed  similarly  with  the  connection  of  subsequent  receivers,  then  press  the  central 
button and exit the menu.  

Caution! 

The pairing mode is available for 10 minutes after the receiver has been connected to 
the mains! 

Factory-established  thermostat-receiver  pairs  are  paired,  however,  pairing  may  be 
repeated if necessary.  

Summary of Contents for 4020TXRX

Page 1: ...e of 5 C 35 C The thermostat is programmable in daily operating cycles 2 BASIC THERMOSTAT FUNCTIONS Does not require leading cable connections between the thermostat and the controlled device User fri...

Page 2: ...Prior to mounting or dismantling the set make sure that the heating cooling system is de energized Voltages hazardous to life may be present on receiver output cables power supply phase voltage there...

Page 3: ...rving the correct polarity There are installation markings in the battery compartment Then install snap the thermostat onto the base CAUTION Use only alkaline AAA batteries to power the thermostat Do...

Page 4: ...hand button Press the right hand button again select comfort or reduced temperature Use buttons to set the desired temperature value confirm with the central button In order to disable the function ho...

Page 5: ...ton Active interlock is indicated by displaying the icon The interlock is active after 10 minutes The interlock is disabled in the same way This function is not active by default Temperature sensor co...

Page 6: ...ermostat and each receiver has a unique number that distinguishes it from others It is not possible for any thermostat not paired with the particular receiver to interfere with the operation of anothe...

Page 7: ...ce for a strong range and once for sufficient range 13 2 No radio communication If the communication between the thermostat and the receiver is interrupted e g discharged batteries and if this conditi...

Page 8: ...stat stand receiver 230 V 50 Hz plug socket Thermostat weight without batteries thermostat without batteries 120 g Receiver 170 g Frequency of operation 868 MHz Maximum power of transmission 25 mW War...

Page 9: ...s and nature resulting from the possible presence of hazardous components in the equipment and batteries and inaccurate storage and processing of such equipment batteries and accumulators Households p...