EUROSTER 11Z USER MANUAL
6
13 SPECIFICATIONS
a) Mains
230 V 50Hz
b) Current consumption
max. 7 mA (1.6 W)
c) Output rated load
3 A
d) Length of cables:
Controller power supply
1.5 m
CH pump power supply
1.5 m
UHW pump power supply
1.5 m
UHW tank temperature sensor
5 m
CH boiler temperature sensor
1,5 m
e) Dimensions (width x height x depth) 150 x 90 x 54 mm
14 KIT CONTENTS
a) controller box with 2 temperature sensors
b) sensor hose clips
c) box fasteners/anchors
d) this Installation & Operation Manual
e) template to drill holes for fasteners/anchors
15 CONNECTION DIAGRAM
Diagram presented below is simplified (not every element necessary to correctly operate the
system is shown).
Central heating pump control mode
1.
EUROSTER 11Z controller
2. UHW tank temperature sensor
3. UHW tank
4. UHW pump
5. CH boiler
6. CH Temperature sensor
7. CH pump
8. Radiator (heat load)