EUROSTER 11Z USER MANUAL

1

EUROSTER 11Z

 

CENTRAL HEATING / UTILITY HOT WATER PUMP CONTROLLER

MANUFACTURER: P.H.P.U. AS, Polanka 8a/3, 61-131 Poznań, POLAND

1

INTRODUCTION

Carefully study this user manual to learn how to correctly operate the EUROSTER 11Z central 

heating / utility hot water pump controller.

2

FIELD OF APPLICATION

EUROSTER 11Z 

is a modern microprocessor-based controller used to control central heating 

(CH) system circulation pump and utility hot water (UWH) tank pump. The controller may be 

turned in the UHW priority mode. 
The controller will turn the CH system circulation pump OFF if the boiler temperature has 

dropped below some defined preset temperature. The controller will turn the UHW tank pump 
ON if the tank temperature has dropped below some defined preset temperature. Additionally 

the controller protects the UHW tank against chill-out in case temperature of the heat source is 
too low (e.g. since the boiler is extinct).
The UHW priority mode may be used to heat the UHW tank up as soon as possible.
The  

EUROSTER   11Z

  controller   features   the   ANTY   STOP 

function that prevents idle pump rotors against seizing. Once 
the   heating   season   is   over,   every   14   days   the   function 

automatically turns ON the pumps for 30 seconds. To that end 
the controller must be left powered up.

3

VISIBLE CONTROLLER ELEMENTS 

1. 230 VAC~ mains input 
2. 230 VAC~ power supply to CH pump 

3. 230 VAC~ power supply to UHW pump 
4. Input for UHW temperature sensor cable 

5. Input for CH water temperature sensor cable 
6. Mains switch 

7. LCD display
8. Knob

Summary of Contents for 11Z

Page 1: ...e The controller will turn the UHW tank pump ON if the tank temperature has dropped below some defined preset temperature Additionally the controller protects the UHW tank against chill out in case te...

Page 2: ...on an unshielded boiler outlet pipe as close to the boiler as possible install UHW tank temperature sensor at the tank point specially designed for that purpose using hose clips tighten the sensors t...

Page 3: ...the display while the ANTY STOP function turns on the pump State of the system is shown on the display If the controller is being turned on for the first time set the desired controller presets see s...

Page 4: ...heat up faster if this mode of operation is activated the CH system pump is unconditionally turned OFF 7 Boiler temperature sensor correction A constant added to all values measured by boiler tempera...

Page 5: ...tank temperature surplus Tboiler Ttank Tsurplus 3 C The pump should run to prevent chilling out the tank until the difference decreases to the surplus minus 3 C Tboiler Ttank Tsurplus 3 C 10 THE ANTY...

Page 6: ...x depth 150 x 90 x 54 mm 14 KIT CONTENTS a controller box with 2 temperature sensors b sensor hose clips c box fasteners anchors d this Installation Operation Manual e template to drill holes for fas...