6. SETTING OF THE LEVEL DETECTOR
This operation must be done in the 5 minutes following the starting-up of the mixer.
Otherwise, the level detector will be locked.
1.
Place a piece of white cardboard in the tank of the machine* (photo 1), 2 centimeters above the
minimum level of product desired (plan 2)
2.
Place a screwdriver on the level detector (photo 3) until the Y and Z LED flash quickly (6 Hz).
Remove the screwdriver, the detector is reset.
3.
Place the screwdriver again until the Y and Z LED flash slowly (2 Hz), remove the screwdriver.
4.
Place the screwdriver a third time, Y and Z LED will stay on. Remove the screwdriver.
5. Repeat the previous step one time.
*this step can be done by filling the tank with product instead of using the white cardboard.
When the product in the tank of the machine will reach the minimum level set previously, the mixer will
start again (if AUTO mode is activated - (light (L10) lighted up)) until the tank is filled to the setting level.
Reached the setting level, the mixer will work during another 25 seconds (temporization of mixing).
Depending on the machine flow-rate, increase or decrease the temporization of mixing by following the
procedure below.
Setting of the temporization of mixing
1.
Press the MANU/STOP button (2) then press ON/OFF (1) and keep the two buttons pressed.
2.
Release the MANU/STOP button (2) only, the (L4) light flashes.
NB: the ON/OFF button (7) must be maintened pressed till the end of the procedure.
3.
Press MANU/STOP (2) once, the (J) display shows "H02". Press the MANU/STOP button (2) a
second time, the light (L4) flashes and the display (J) shows 25 seconds.
4.
Set the new temporization time with help of the (4) and (5) buttons.
5. Once the temporization time is chosen, press the AUTO button (3) to validate the operation.
6. Release ON/OFF (1).