User manual - Compact-Pro Joint 20
202002-402A-ENG
P10
4. USE OF THE MACHINE
4.1. PREREQUISITES
•
The electric connection has to be 230 V - 16 A - 50 or 60 Hz with a 3 x 2,5 mm² cable reel of 40m
maximum, completely unreeled.
•
One push on the MANU/AUTO button (2) makes the pump start working and the (L2) light lights up.
• One push on the button REVERSE (3) makes the product pump turn in reverse mode and the light (L4)
lights up.
• In AUTO mode, the pump starts only at the opening of the lance.
•
In MANU mode, the pump works continuously.
• After a prolonged standstill, it is possible that the pump might be blocked. If this is the case, alternately
turn the pump forwards and backwards for 5 second sequences. As soon as the engine starts to turn
normally, the pump is unblocked.
•
Check every month that the machine’s automatic lubricator is working properly. The level of grease in the
cartridge should decrease steadily. The absence of grease can seriously damage the machine.
PRESSURE VALUES:
- Ready-to-use product: from 12 to 15 bars
- Traditional product: from 5 to 8 bars
PRESSURE CONTROL AND ADJUSTMENT:
(at least once a week)
•
Install the pressure controller on the machine outlet with the valve in the open position.
•
Put water in the tank.
•
Switch the machine on (button (1)).
• Set the machine to 100% using buttons (4) & (5).
• Press MANU/AUTO (2), the machine starts.
• Close the controller valve and read the value on the manometer (C).
•
Adjust the desired value with the 3 pump screws (tighten from the external screw to the screw on the
tank side, equally).
• Adjust by closing the valve and reading the manometer
(repeat the adjustment operation until the
correct pressure is obtained)
.
Never use petroleum-based products in the pump, as they may damage it.
Never run the pump without water or product.
It is imperative to replace the automatic motor flange lubricator (G) every 6 months.