202002-400A-ENG
User manual - JETPRO 100-7, 120-7, 130-7
P15
6. CLEANING PROCEDURE
6.2. AFTER DROPLET USE
1.
Remove the nozzle and place it in a bucket of water.
2. With the lance open, speed on 30, press the button (2) to empty the tank to the maximum.
3. Press the button (2) again to stop the machine.
4. Disconnect the droplet box connector and the air hose from the lance.
5. Open the valve (E) and proceed to the cleaning of the tank. Once the tank is clean, close the valve
(E).
6.
Put water with a little liquid soap in the tank.
7.
Remove the filter from its housing (B) and clean it.
8. Disconnect the product hose from the pump nose (A).
9. Set the speed to 30, turn the machine on for 30 seconds to clean the pump.
10.
Stop the machine (button (2)) and finish cleaning the pump nose ( product outlet).
11. Disconnect the lance from the hose.
12. Put the cleaning ball in the hose and reconnect it to the machine.
13. Still at speed 30, turn the machine on, the product starts to come out.
14. When the ball comes out of the hose, repeat the operation.
15. Clean the lance and the nozzle.
16.
Open the valve (E) to empty the water remaining in the tank, then close the valve.
17.
Put some water with storage liquid back into the tank (up to the level of the grid).
18.
Still at speed 30, switch on for about one minute.
19.
The machine is clean. Before storing it, make sure that there is still some water/storage liquid mixture
at the bottom of the tank.
The direct projection of water under pressure onto the control panel has to be stopped at
the risk of water infiltration into the electric box. Proceed by simply cleaning with a humid
sponge.
Before unscrewing the hose, make sure it is not under pressure anymore.