Only use a hoist according to local safety regulations. 
Never allow sharp bends in lifting cables and chains.  
It is strictly forbidden to dwell or stay in the risk zone under a lifted 
load. Never lift the unit over people or residential areas. Never 
leave a load hanging on a hoist. Lifting acceleration and 
retardation shall be kept within safe limits.  
To lift heavy parts, a hoist of ample capacity, tested and approved 
according to local safety regulations, shall be used. 
Lifting hooks, eyes, shackles, etc. shall never be bent and shall 
only have stress in line with their design load axis. 
The capacity of a lifting device diminishes when the lifting force is 
applied at an angle to its load axis. 
For maximum safety and efficiency of the lifting apparatus all 
lifting members shall be applied as near to perpendicular as 
possible.  
A hoist has to be installed in such a way that the object will be 
lifted perpendicular. 
If that is not possible, the necessary precautions must be taken to 
prevent load-swinging, e.g. by using two hoists, each at 
approximately the same angle not exceeding 30° from the vertical. 

(28) 

 

 

WARNING! 

– Consult the instruction and maintenance manual of 

the engine and the alternator before carrying out maintenance.  
Improper maintenance, or failure to correct a problem before 
operation, can cause a malfunction in which you can be seriously 
hurt or killed. 
Always follow the inspection and maintenance recommendations 
and schedules mentioned in the instruction and maintenance 
manual of the engine and the alternator. 

 
 

3. SHORT DESCRIPTION OF THE GENERATING SET 

 
Type: EP10000E H/MA: 10 kVA max. / 9 kVA cont. 

 39 A 1x230 V 

Type: EP13500TE H/S: 13.5 kVA max. / 12 kVA cont. 

 20 A 1x230 V / 14 A 

3x400 V 
Type: EP12000TE-IP54 H/So: 12.5kVA max. / 11kVA cont. - 17A 1x230V / 13A 
3x400V 
Type: EP12000TE-IP54 H/GTS: 12.5kVA max. / 11kVA cont. - 23A 1x230V / 13A 
3x400V 
Type: EP12000E H/S: 12 kVA max. / 10.8 kVA cont. 

 47 A 1x230 V 

Type: EP16000TE H/S: 16 kVA max. / 14.4 kVA cont. 

 23 A 1x230 V / 16 A 

3x400 V 
Type: EP14000E H/S:  13.5 kVA max. / 12   kVA cont.

 52A 1x230V 

Type: EP18000TE H/S: 17.5 kVA max. / 16   kVA cont.

 23A 1x230V / 18A 

3x400V 
 
Weight:  

Summary of Contents for EP10000E H/MA

Page 1: ...4 H So EP12000TE IP54 H GTS EP13500TE H S EP12000E H S EP16000TE H S EP14000E H S EP18000TE H S Content 0 INTRODUCTION 1 SAFETY INSTRUCTIONS 2 CE MARK NOISE LABEL AND PICTOGRAMS 3 SHORT DESCRIPTION OF...

Page 2: ...use at least 1m away from buildings or other equipments Keep children and pets away from the generator when it is in operation Gasoline is extremely flammable and explosive under certain conditions Re...

Page 3: ...to touch the muffler while it is still hot Let the engine cool down before storing the generator indoors To prevent scalding pay attention to the warning marks attached to the generator Keep in mind...

Page 4: ...e pictograms are typical for a certain option or special type of generating set Therefore not all pictograms necessarily appear on the standard generating set EP_B 1 Here you can fill the tank with fu...

Page 5: ...nnected Follow the instructions in this manual concerning the use of an earth pin 22 WARNING Hot surface Can cause burns Hot engine and hot exhaust system can cause serious and even lethal injuries Ne...

Page 6: ...st has to be installed in such a way that the object will be lifted perpendicular If that is not possible the necessary precautions must be taken to prevent load swinging e g by using two hoists each...

Page 7: ...ing to 2006 42 EG The main components of the generating set are GX630 GX690 iGX800 air cooled gasoline engine 3000rpm with starting control panel the alternator the alternator control panel the fuel t...

Page 8: ...y for EP12000E EP16000TE EP14000E and EP18000TE first put the starting key in the position ON initiation injection system only for EP14000E and EP18000TE start the engine with the starting key close t...

Page 9: ...0 to 200W is connected it will return to its nominal speed 3000rpm Note it can happen that the A I S function does not react on some small electronic charges When this occurs turn off the A I S system...

Page 10: ...quare pictogram on the machine there is no limitation in the quantity of charges connected at the same time on the generating set Contact your distributor for details on the above subject Still you ha...

Page 11: ...o alternator EP16000TE 217000118 FT2MGS 18kVA 230 400V Sincro alternator EP18000TE 217714139 SSG132LA2 R IP54 AVR 12kVA 230 400V SAEJ609B 3000tpm EP12000TE IP54 So 218000112 DWG 12 5 6 2EE IP54 12 5 6...

Page 12: ...FT with 2 diode bridges 398000630 air cleaner element GX630 GX690 iGX800 398200630 oil filter GX630 GX690 iGX800 399000030 condensator 30 F EP12000E 399000035 condensator 35 F EP12000E A00002000 spark...

Page 13: ...ehicle avoid a place exposed to direct sunlight When the generator is left in an enclosed vehicle for a longer period of time high temperature inside the vehicle could cause fuel to vaporise resulting...

Page 14: ......

Page 15: ......

Page 16: ......

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...ttr io 9 lii r 2 INDICATOR IGN colL 1 S PLUG 1 BATTERY STARTER FUSE l54 o SB LG _ P GR BE COLOR COMB RA r w L REG RECT R B Y B I I I I I I I Only on engine with SV on control box Only on engine with O...

Reviews: