EuropAce EWH 5451T Instruction Manual Download Page 4

3

TABLE 1-ELECTRICAL LOADING TABLE

HEATER UNIT INSTALLATION

1) Installation instruction f

   1.1) Install the Undersink Heater as close as possible to the main hot water dra

points.

   1.2) Leave a minimum of 5’’ of clearance on all sides for servicing.

   1.3) Remove plastic cover. (Fig. 3 )

   1.4) Mount unit securely to wall by putting two screws through mounting holes. 

           Screws and plastic wall plugs for mounting are provided. (Fig. 4)

2) The unit is to be installed in a closed, frost-free room. The unit is to be installed vertically 

    (Hot water connection downwards).

3) The unit can be installed in any location, conceal in the ceiling, below washbasin or even wall mounted. 

HEATER UNIT INSTALLATION DIAGRAM

Mounting hole (A)

Fig. 4

Fig. 1

Fig. 2

248mm

155mm

Fig. 3

83mm

Mounting hole (B)

  

  Voltage      Power     Current   

      (AC)            (kW)           (A)           

                 Conductor Size (csa)
  mm     Conduit Cable    Flexible Cable

  

  On/ O

Fuse /

  Switch (A)     MCB (A) 

       

240V 

50/60 Hz

 2.4         10.0         2.5        7 / 0.67mm         50 / 0.25mm            20                20
 3.6         

 4.9         20.4         4.0        7 / 0.67mm         56 / 0.25mm            32                32

230V 

50/60 Hz

 3.3         14.4         2.5        7 / 0.67mm         50 / 0.25mm            20                20

 4.5         19.6         2.5        7 / 0.67mm         50 / 0.25mm            32                32

 6.0         25.0         4.0        7 / 0.85mm         56 / 0.30mm            32                32

220V 

50/60 Hz

 2.4         10.9         2.5        7 / 0.67mm         50 / 0.25mm            20                20

 3.5         15.9         2.5        7 / 0.67mm         50 / 0.25mm            20                20

 4.5         20.5         2.5        7 / 0.67mm         56 / 0.25mm            32                32

 6.0         27.3         4.0        7 / 0.85mm         50 / 0.30mm            32                32

 5.5         25.0         4.0        7 / 0.85mm         56 / 0.30mm            32                32

(Malaysia Modal)

             15.0         4.0        7 / 0.85mm         50 / 0.30mm            20                20

3

TABLE 1-ELECTRICAL LOADING TABLE

HEATER UNIT INSTALLATION

1) Installation instruction f

   1.1) Install the Undersink Heater as close as possible to the main hot water dra

points.

   1.2) Leave a minimum of 5’’ of clearance on all sides for servicing.

   1.3) Remove plastic cover. (Fig. 3 )

   1.4) Mount unit securely to wall by putting two screws through mounting holes. 

           Screws and plastic wall plugs for mounting are provided. (Fig. 4)

2) The unit is to be installed in a closed, frost-free room. The unit is to be installed vertically 

    (Hot water connection downwards).

3) The unit can be installed in any location, conceal in the ceiling, below washbasin or even wall mounted. 

HEATER UNIT INSTALLATION DIAGRAM

Mounting hole (A)

Fig. 4

Fig. 1

Fig. 2

248mm

155mm

Fig. 3

83mm

Mounting hole (B)

  

  Voltage      Power     Current   

      (AC)            (kW)           (A)           

                 Conductor Size (csa)
  mm     Conduit Cable    Flexible Cable

  

  On/ O

Fuse /

  Switch (A)     MCB (A) 

       

240V 

50/60 Hz

 2.4         10.0         2.5        7 / 0.67mm         50 / 0.25mm            20                20
 3.6         

 4.9         20.4         4.0        7 / 0.67mm         56 / 0.25mm            32                32

230V 

50/60 Hz

 3.3         14.4         2.5        7 / 0.67mm         50 / 0.25mm            20                20

 4.5         19.6         2.5        7 / 0.67mm         50 / 0.25mm            32                32

 6.0         25.0         4.0        7 / 0.85mm         56 / 0.30mm            32                32

220V 

50/60 Hz

 2.4         10.9         2.5        7 / 0.67mm         50 / 0.25mm            20                20

 3.5         15.9         2.5        7 / 0.67mm         50 / 0.25mm            20                20

 4.5         20.5         2.5        7 / 0.67mm         56 / 0.25mm            32                32

 6.0         27.3         4.0        7 / 0.85mm         50 / 0.30mm            32                32

 5.5         25.0         4.0        7 / 0.85mm         56 / 0.30mm            32                32

(Malaysia Modal)

             15.0         4.0        7 / 0.85mm         50 / 0.30mm            20                20

Summary of Contents for EWH 5451T

Page 1: ...uropAce Oscillating Power Fan For safety purpose please read this operating instruction manual carefully before using and keep it for future reference MADE IN MALAYSIA Reset ated in Water Heater EWH 5...

Page 2: ...Inlet Connection 11 Pressure Relief Valve 12 Mesh Filter 13 9 10 4 5 6 7 11 12 8 13 Terminal Block PART IDENTIFICATION 1 11 12 1 2 3 1 Front Cover 2 LED Indicator 3 Temperature Control Knob 4 Heater...

Page 3: ...m inlet water pressure of 6 Bar liter min to trigg ow switch abnormal rise in water temperature 2 6 2 SAFETY INFORMATION Products manufactured by us are safe provided they are installed used and maint...

Page 4: ...0 30mm 32 32 5 5 25 0 4 0 7 0 85mm 56 0 30mm 32 32 Malaysia Modal 15 0 4 0 7 0 85mm 50 0 30mm 20 20 3 TABLE 1 ELECTRICAL LOADING TABLE HEATER UNIT INSTALLATION 1 Installation instruction f 1 1 Install...

Page 5: ...pressure gets higher than 6 0 bars water will drip from this discharge and incoming water pipe pipe 4 continue from HEATER UNIT INSTALLATION DIAGRAM Fig 5 PressureReliefValvemustbe installedtoinleteve...

Page 6: ...WHENEVER NECESSARY USE ONLY THREAD OR SEALING TAPE THE HEATER TANK MUST BE FILLED UP WITH WATER BEFORE TURNING ON THE ELECTRICITY SUPPLY TO PREVENT ANY DRY BURNT DAMAGE TO THE HEATING ELEMENT CHECK I...

Page 7: ...supply and Stop Valve the wat ow through the outlet Switch on the electrical supply LED indicator will light up in Blue Color Turn the Temperature Control Knob to ON the LED Indicator will light up i...

Page 8: ...ER REGULARLY Read the section SAFETY INFORMATION If any abnormal condiiton to the water heater switch OFF the mains for repair service Special skill is required for repairing NEVER try to repair the u...

Page 9: ...trictly under the instruction for operation as provided by the manufacturers or the appliance 3 That if any time during the warranty period any part or parts of this appliance is removed tampered modi...

Page 10: ...o selected models of Stand Fans selected models of Oscillation Power Fans selected models of Air Purifiers Walk in warranty Heating Element warranty applies to selected models of Electric Ovens select...

Page 11: ...control control knob buttons filter UV lamp oven tray wooden rack exhaust hose fixtures panels cover lid and lever plastic parts fan blades blade guard inner pots brushes water tanks attach ments made...

Page 12: ...rategic com sg Twin City Portable Casement Aircons Tel 6291 0800 Email portableac strategic com sg Jia Yue Refrigerators Washing machines Cookers other major appliances Tel 6289 0802 Email mda strateg...

Reviews: