Page:4 Castle Care-Tech
S
ystem Overview
Inputs on main
control panel
10 fully programmable inputs
Input configuration
Double end of line (4K7 Alarm, 2K2 Tamper)
Double end of line (4K7 Alarm, 4K7 Tamper)
Double Pole
Input Types
Unused, Fire, Hold Up, 24 Hour, Intruder, Final
Exit, Entry Route, ER (FX in part), FX (ER in part),
Keyswitch Latched, Keyswitch Pulsed
Programmable
Outputs
PGM, Bell, 4 Outputs on Inputs 7,8,9 and 10
(programmed either as an input or output)
Output Types
Not Used, Fire, Hold Up Any, Intruder Any, Tamper Any,
Set Fail, Entry Deviation, Siren Any, Strobe Any, Exit
Starts Any, Final Set Any, Strobe Set Fail, Keyswitch
Unset, Entry/Exit, Lights, Restore 1, Restore 2, PIR
Latch 1, PIR Latch 2, Mains Good, Detr Indn Enable,
Follow Test, Off During Test, Detr Walk Test, Mains Fail,
Battery Fault, Low Volts, Global Fault 1, Global Fault 2,
Engineer Access
Keypad
Contemporary LCD Keypad 32 Character
Number of Keypads
4
Arming Options
Timed, Final Door, Timed/Final
User Codes
30 user codes, 1 Master Manager, 1 Engineer
Logs
500 Mandatory, 200 Optional
Fuses
AUX, Bell, RS485 Bus, Battery
Tampers
Case Tamper and Siren Tamper
Summary of Contents for 10V6.e
Page 1: ...2x I n s t a l l a t i o n M a n u a l RINS1211 4 EN50131 1 2x...
Page 2: ......
Page 18: ...Page 18 Castle Care Tech...
Page 19: ...Castle Care Tech Page 19...