Castle Care-Tech Page:15
C
onnections
Output
Connections
The
EURO
mini
supports up to 7 outputs. 4 of the outputs are shared with inputs
on the system, therefore if the outputs are used (see Change Outputs in the
programming manual), inputs 7 to 10 become disabled. All outputs on the
system are negative applied and cannot be altered.
The example below shows how to connect a typical 12V dialler.
BELL
BUS
BATTERY
AUX
+12V
GND
P
G
M
A
U
X+
S
PK
S
TB
B
EL
L T
R
B
-
B
+
1 2 3 4 5 0v +12V
Example
Auto Dialler
Inputs
Auxillary
In this example the inputs
are programmed as outputs
See ‘Change Outputs’ section
in the Programming manual.
All outputs are negative applied
Remove for DP
Z1 COM Z2 COM +12V Z3 COM Z4 Z5 COM Z6 COM +12V Z7 COM Z8 Z9 COM Z10 D1- D2+ D3 D4 - BAT + GND