Service, maintenance and repairs
This manual clearly makes a distinction between service
maintenance and repair jobs which have to be carried out by
the user and those which have to be exclusively carried
out by well trained and authorised service engineers.
•
Remove the power connector when cleaning and/or maintenance.
•
Always use tools, parts, materials, lubricants and service techniques
that have been approved by the manufacturer. Never use worn tools
and ensure that tools are not left behind in or on the product.
•
Do not carry out any service, maintenance or repairs on the product
before it has been protected against unintended starting.
•
Safety features removed for servicing, maintenance or repair shall be
re-installed immediately and checked for proper functioning.
•
Regularly clean the inside of the housing.
•
Clean or replace the filters in time.
4
USED PRODUCTS AND THE ENVIRONMENT
PACKAGING MATERIAL
The purpose of the packaging is to protect the product during
transport. It consists of the following substances which can be
reused:
- (corrugated) cardboard
- polyethene foil
- untreated wood
Do not dispose of the packaging material in the industrial
waste, but ask your municipal sanitation department where to
dispose of the material.
Product
Products which you would like to dispose of may still contain valuable
substances and materials. Do not dispose of the product in the industrial
waste, but ask your municipal sanitation department about the
possibilities for reuse or environmentally safe processing of the material.
5
TECHNICAL SPECIFICATIONS
5.1
Technical specifications
MEZZO - ESPACE
Power consumption
with poster display
without poster display
Stand-by 105 W
75 W
In operation 240 W
210 W
Supply voltage and frequency 230V/1~/50-60Hz
Airflow
700 m
3
/h
Noise level
outside 48.4 dB(A) - inside 54.1 dB(A)
Filter efficiency
99.997%
Weight
Mezzo
530 kg
Weight
Espace
605 kg
Dimensions
Mezzo
2200 x 1215 x 2165 mm
Dimensions
Espace
2200 x 1715 x 2165 mm
Ash container capacity
8000 cigarette ends per cabinet
PLAZA - DOUBLE PLAZA
Power consumption
with poster display
without poster display
Stand-by
Plaza
210 W
150 W
In operation
Plaza
480 W
420 W
Stand-by
Double Plaza
420 W
300 W
In operation
Double Plaza
960 W
840 W
Supply voltage and frequency 230V/1~/50-60Hz
Airflow
Plaza
1400 m
3
/h
Airflow
Double Plaza
2800 m
3
/h
Noise level
outside 48.4 dB(A) - inside 54.1 dB(A)
Filter efficiency
99.997%
Weight
Plaza
975 kg
Weight
Double Plaza
1950 kg
Dimensions
Plaza
3430 x 2200 x 2165 mm
Dimensions
Double Plaza
4524 x 3453 x 2165 mm
Ash container capacity
8000 cigarette ends per cabinet
6
GENERAL DESCRIPTION
The Smoke ‘n Go smoking cabins are ideal if you want smokers and
non-smokers to stay in visible contact with each other. The combination of
intensive air cleaning and the odourless storage of ash and cigarette ends
ensures that the surrounding area remains free from annoying smoke and
smells. The smoking cabins are flexible in size and equipped to fit any
interior. For situations in which smoking is only allowed in restricted areas,
the smoking cabin can be mounted with sliding doors, optionally with a
self-closing mechanism. When dealing with a frequently visited public
area the smoking cabins PA (Public Area) are suitable with its double ashtray
(large) with matching ash container, its adjusted start/stop system, and its
gas oxidation filter.
7
INSTALLATION
For a correct installation we refer to the Smoke ‘n Go installation manuals.
8
MAINTENANCE
Take the necessary care when performing the maintenance and cleaning
described below. The indicated maintenance intervals may vary depending
on the specific work and local conditions. It is therefore recommended to
thoroughly inspect the product annually in addition to the specified periodic
maintenance. Contact your supplier for this specific subject.
WARNING
Overdue maintenance can cause fire.
WARNING
Always switch OFF the machine and remove the connector from
the wall socket before carrying out the activities below.
First read the maintenance regulations at the beginning of this
manual.
8.1
Replace filters
Clean or replace the filters:
•
when damaged
•
when the extraction capacity becomes inadequate