4

Use screws with a size of 4 x 40 and matching wall plugs for mounting the 
bottom part of the enclosure to the wall. Some walls do not need the use of 
wall plugs and in that case the enclosure can be screwed to the wall without 
the need for drilling.

Guide the cable from the DFI filter to the RC-MSA and install it in accordance 
with national regulations.

CONNECTIONS

The electrical connections have to be made with a 4 core cable. There is no 
need for an electrical screened cable.

For cable lengths till 50 meters the diameter of the cores should be 4 x 
0,5sqmm. and for larger distances bigger cores need to be used like 4 x 
1,0sqmm.

ATTENTION

Remove the CEE power plug before connecting the 
RC-MSA cable.

Internal connections

Make the connections according to the drawing below

External connections

Remove the lid at the top from the DFI filter using a Torx tool T15. Enter the 
cable through one of the pre-assembled cable glands. Connect the cable to 
the terminal strip according to the diagram.

REMARK

See Installation manual DFI if more filters need to be connected 
via the RS485 bus.

MAINTENANCE

The RC-MSA does not require special maintenance. The enclosure can be 
cleaned with a mild detergent.

PROBLEM SOLVING

When the system is not working properly consult the following checklist to 
see if you can solve the problem yourself. If this is not the case you need to 
call help from educated, skilled and authorized technicians.

WARNING

Always check if the malfunction is from electrical or  
mechanical origin. Activities or repairs to the electrical 
 system may only be performed by educated, skilled and 
authorized service technicians.

Always switch OFF the DFI and remove power supply before starting the 
repair. Read the repair regulations at the start of this manual.

REMARK

A nummer of problems listed in the table may also be caused 
by connected devices in the system. In this manual the focus is 
on the problems and solutions caused by Remote RC-MSA itself.

Problem

Possible cause

Solution

RC-MSA does nothing.

Switched off DFI (MASTER).

Switch on the DFI (MASTER).

RC-MSA gives flashing green LED.

Several filters (SLAVES) are connected and those
do not respond correctly due to malfunction.

Troubleshooting on DFI.

RC-MSA gives flashing green LED.

Several filters (SLAVES) are connected and those

do not respond correctly because one or a few are

switched off.

Switch on the DFI(‘s).