INSTALLATION 
Notes 

  Prior to installation. Please ensure that any existing or proposed roof ducting installation for connection to 

this appliance is suitable and complies with local municipal building codes and other statutory / building 
regulations. If you are unsure, please check with appropriate authorities or a qualified roof ducting installer. 

  Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air 

is fulfilled.  

  Ensure that the fully installed canopy has the clearance of at least 600mm between the lowest part of the 

hood and the cooking hob.  

  Before drilling any holes check the wall and ceiling are clear of any electrical cables, pipes etc. 

  The canopy rangehood is of wall-mount type. It must not be mounted / suspended from the ceiling.  

  The unit is supplied with mounting brackets that must be fixed onto the wall first. If the wall where the 

rangehood is to be mounted on is a cavity wall then a solid noggin or stud (horizontal or vertical 
timber/metal house framing behind the wall) is required for the mounting bracket to screw into. Due to the 
heavy weight of the rangehood, it must not be mounted onto the plasterboard wall without solid support 
from behind the wall surface. 

  For dimensions, see “Product Dimensions” diagrams below. 

 

This rangehood is designed for operation in either one of the following ways: 

 

Ducted System

 – The cooking exhaust fumes are extracted and released external to the building. 

Requires professional installation of flue piping to external of the house through ceiling or wall cavity space 
prior to installation of rangehood. A flexible flue duct (150mm dia.) is supplied with the rangehood 

 

Recirculating System

 – The cooking exhaust fumes are extracted and recirculated internally within the 

kitchen. Requires two additional (charcoal / carbon type) filters to be installed within the rangehood, which 
is sold as a separate accessory. 

 

Product Dimensions 

 

EUC60GS 

 

EUC90GS 

 

EUC90SS 

 

EUC91SS 

 

Installation Procedure – Ducted System

 

1.  Engage an authorised person to install the ducting to the required position. 
2.  Measure and mark the position on the wall for the flue (top-most section, see figure 3c below, marked ‘C’) 

mounting bracket to be fixed. This mounting bracket is to be located at the top rear of the flue cover. 

3.  Measure and mark the position on the wall for the rangehood main unit (see figure 1a, & 1b) mounting 

bracket to be fixed. A suitable method is to measure the distance from the base of the rangehood to the 
hanging slots as shown in Figure (2a) below. 