INSTALLATION
Notes
•
Prior to installation. Please ensure that any existing or proposed roof ducting installation for connection to
this appliance is suitable and complies with local municipal building codes and other statutory / building
regulations. If you are unsure, please check with appropriate authorities or a qualified roof ducting installer.
•
Attention should be given to ensure that any applicable regulations concerning the discharge of exhaust air
is fulfilled.
•
Ensure that the fully installed canopy has the clearance of at least 600mm between the lowest part of the
hood and the cooking hob.
•
Before drilling any holes check the wall and ceiling are clear of any electrical cables, pipes etc.
•
The canopy rangehood is of wall-mount type. It must not be mounted / suspended from the ceiling.
•
The unit is supplied with mounting brackets that must be fixed onto the wall first. If the wall where the
rangehood is to be mounted on is a cavity wall then a solid noggin or stud (horizontal or vertical
timber/metal house framing behind the wall) is required for the mounting bracket to screw into. Due to the
heavy weight of the rangehood, it must not be mounted onto the plasterboard wall without solid support
from behind the wall surface.
•
For dimensions, see “Product Dimensions” diagrams below.
This rangehood is designed for operation in either one of the following ways:
•
Ducted System
– The cooking exhaust fumes are extracted and released external to the building.
Requires professional installation of flue piping to external of the house through ceiling or wall cavity space
prior to installation of rangehood. A flexible flue duct (150mm dia.) is supplied with the rangehood
•
Recirculating System
– The cooking exhaust fumes are extracted and recirculated internally within the
kitchen. Requires two additional (charcoal / carbon type) filters to be installed within the rangehood, which
is sold as a separate accessory.
Product Dimensions
EUC60GS
EUC90GS
EUC90SS
EUC91SS
Installation Procedure – Ducted System
1. Engage an authorised person to install the ducting to the required position.
2. Measure and mark the position on the wall for the flue (top-most section, see figure 3c below, marked ‘C’)
mounting bracket to be fixed. This mounting bracket is to be located at the top rear of the flue cover.
3. Measure and mark the position on the wall for the rangehood main unit (see figure 1a, & 1b) mounting
bracket to be fixed. A suitable method is to measure the distance from the base of the rangehood to the
hanging slots as shown in Figure (2a) below.