EN
101
country, any of the connections in the
fi
gure below may be required. In such
a case, contact local authorities to learn
the correct gas connection.
The Cooker must be installed and main-
tained by a suitably quali
fi
ed gas regis-
tered technician in accordance with cur-
rent safety legislation.
WARNING:
Do not use a naked
fl
ame to check for gas leaks.
2.4 Gas Conversion (If available)
Your appliance is designed to be oper-
ated with LPG/NG gas. The gas burn-
ers can be adapted to di
ff
erent types
of gas, by replacing the corresponding
injectors and adjusting the minimum
fl
ame length suitable to the gas in use.
For this purpose, the following steps
should be performed:
Changing injectors
Hob burners
Cut o
ff
the main gas supply and unplug
the appliance from the mains electrical
supply.
• Remove the burner caps and the
adapters.
• Use a 7 mm spanner to unscrew the
injectors.
• Replace the injector with the ones
from the gas conversion kit, with the
correct diameters for the type of gas
that is going to be used, according to
the gas injector table.
Adjusting the reduced
fl
ame position
First of all, make sure that the appliance
is unplugged from the mains electrical
supply and that the gas feed is open.
The minimum
fl
ame position is adjusted
with a
fl
at screw located on the valve.
For valves with a
fl
ame failure safe-
ty device, the screw is located on the
side of the valve spindle as shown in
the
fi
gures. For valves without a
fl
ame
failure safety device, the screw is locat-
Gas pipe
Seal
Hose
fi
tting
Hose
fi
tting
Gas hose
with collar
Gas pipe
Gas pipe
Seal
Seal
Hose
fi
tting
Hose
fi
tting
Gas hose
with collar
Mechanical
gas hose
Gas pipe
Gas pipe
Seal
Hose
fi
tting
Hose
fi
tting
Hose
fi
tting
Mechanical
gas hose
Mechanical
gas hose
Burner cap
Adapter
Cup
Spanner
Injector