Eurolube Equipment 60230 Service Manual Download Page 6

EUROLUBE EQUIPMENT

Alentec & Orion AB, Grustagsvägen 4, SE-138 40 Älta, Sweden

EMAIL 

[email protected] 

PHONE 

+46 8-747 67 10 

FAX 

+46 8-715 20 74

www.eurolube.com

PART NO 60230 / ART.NR. 60230

ELECTRIC PumP 230 V

6

DECLARATION OF CONFORmITY / DEKLARATION Om ÖVERENSSTÄmmELSE

Krister Tynhage,

Managing Director

Michael Theorin,

Technical Director

Alentec & Orion AB, Grustagsvägen 4, 138 40 Älta Sweden, declares hereby that the products  
are in conformity with the requirements of the Council´s Machinery Directive 2006/42/EEC, 
Electromagnetic Compability 2004/108/EC, and Low Voltage 2006/95/EC.

Älta April 17, 2015

Alentec & Orion AB, Grustagsvägen 4, 138 40 Älta, deklarerar härmed att produkterna är 
tillverkade i överensstämmelse med bestämmelserna i Maskindirektivet 2006/42/EEC, 
Elektromagnetisk Kompabilitet 2004/108/EC, och Låg Volt 2006/95/EC.
 
Älta April 17, 2015

Summary of Contents for 60230

Page 1: ...fluids from IBCs drums or other containers IP55 Allmänt Självsugande elektrisk membranpump för professionell överföring av AdBlue och andra vattenbaserade ej korrosiva vätskor från IBC fat eller andra behållare IP55 TECHNICAL DATA TEKNISKA DATA Max working pressure Max arbetstryck 0 15 MPa Voltage Spänning 230 VAC Power Motor 400 W Capacity Kapacitet Max 30 l min Max suction height Max sughöjd 1 8...

Page 2: ... when pump is under operation as its surface might be hot This pump is not suitable for pumping flammable fluids and can t be operated in explosion risk atmospheres Avoid any accidental contact between the electrical supply and the fluid being transferred Do not lift the pump using the power cord You are pumping a fluid under pressure be careful in case of an accidental breakage in any part of the...

Page 3: ...tten OPERATION DRIFT MAINTENANCE UNDERHÅLL FLUID DELIVERY Please follow these instructions in order to start supplying fluid 1 Run the pump by connecting the switch located in the rear 2 Place the nozzle outlet in the inlet of the container that will be filled 3 Pull the trigger from the nozzle to start dispensing 4 A foot valve and a filter not included are recommended in the suction line for a c...

Page 4: ...205149 PARTS DRAWING SPRÄNGSKISS POS DESCRIPTION 1 Bypass valve kit 2 Pump head kit 3 Fan cover kit 4 Electrical connection kit POS BESKRIVNING 1 Bypassventilsats 2 Pumphuvudsats 3 Fläktskydssats 4 Elektrisk anslutningssats 4 3 2 1 1 8 m 6 feet Backpresure bar Mottryck bar 2 1 5 1 A B C ...

Page 5: ...e Suction blocked Remove the obstacle or replace the suction tube Check that both filter and foot valve work properly Empty suction chamber Add some liquid into the suction chamber SYMPTOM MÖJLIG ORSAK LÖSNING Motor kör inte Ingen elektrisk kraft Kontrollera elektriska anslutningar och eller säkerhetsanordningar Motorfel Kontakta teknisk service Ingen eller låg pumpleverans Låg tanknivå Fyll tanke...

Page 6: ...cal Director Alentec Orion AB Grustagsvägen 4 138 40 Älta Sweden declares hereby that the products are in conformity with the requirements of the Council s Machinery Directive 2006 42 EEC Electromagnetic Compability 2004 108 EC and Low Voltage 2006 95 EC Älta April 17 2015 Alentec Orion AB Grustagsvägen 4 138 40 Älta deklarerar härmed att produkterna är tillverkade i överensstämmelse med bestämmel...