EuroLite TS-3 DMX-Scanner User Manual Download Page 7

20

Occupation of the DIP-switches:

Projector 1 - channels 1-4

On
Off

Starting address

Projector number

& channels

Off

Projector 2 - channels 5-8

On
Off

Projector 3 - channels 9-12

On
Off

Projector 4 - channels 13-16

On
Off

Projector 5 - channels 17-20

On
Off

1

2

4

8

16

32 64 128 256

DIP-switch no.

1

2

3

4

5

6

7

8

9

Setting the DMX-

starting address:

Connection with the mains

This device falls under protection-class I. The electric connection must be carried out by a qualified
employee.

Connect the fixture to the mains with the power-plug.

The occupation of the connection-cables is as follows:

Cable

Pin

International

Brown

Live

L

Blue

Neutral

N

Yellow/Green

Earth

The earth has to be connected!

In general, lighting effects should not be connected to dimming-packs.

OPERATION

After you connected the effect to the mains, the TS-3 starts running. During the Reset, the motors are
trimmed and the device is ready for use within approximately 20 seconds.

Sound-control/Master/Slave-operation

The lamp is automatically ignited as soon as the condensor microphone receives music signals. If the
projector does not react to the music signals, the microphone sensitivity is too low. You can adjust the
sensitivity with the rotary-control on the rearpanel.

You can do without a controller as the TS-3 features a built-in microphone, which provides automatic sound
control.

If you have connected a footswitch to the Blackout-socket, you can lock the light output (Blackout-mode) and
turn it on again.

Please note:

 If you wish to change from one operating mode into another, you either have to switch off the

lamp/activate Blackout-mode or unplug the projector from the mains and plug it again.

Summary of Contents for TS-3 DMX-Scanner

Page 1: ...er a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Important Damages caused by the disregard of this user manual are not subject to warranty The...

Page 2: ...g or operating the device When choosing the installation spot please make sure that the device is not exposed to extreme heat moisture or dust There should not be any cables lying around You endanger your own and the safety of others The minimum distance between light output and the illuminated surface must be more than 0 5 meters Make sure that the area below the installation place is blocked whe...

Page 3: ...oller 4 DMX control channels required Sound controlled via built in microphone Microphone sensitivity adjustable via rotary control Master Slave function 4 high quality stepping motors Automatic lamp off during blackout or when sound signal is missing EFR 15 V 150 W lamp included in the delivery Overview eurolite 1 2 3 4 5 6 7 8 9 1 Housing cover 2 Housing screws 3 Ventilation fan 4 Mounting brack...

Page 4: ... Blackout socket 13 Microphone 14 Sensitivity control 15 Fuseholder 16 Power supply 17 DIP switches INSTALLATION Installing Replacing the lamp For the installation you need one EFR 15 V 150 W GZ 6 35 lamp The lamp has to be replaced when it is damaged CAUTION During the operation the lamp reaches temperatures of up to 600 C Before replacing the lamp unplug mains lead and let the lamp cool down app...

Page 5: ...le in the mounting bracket Adjust the desired inclination angle via the mounting bracket and fix the bracket screws tightly Master Slave operation The master slave operation enables that several devices can be synchronized and controlled by one master device On the rear panel of the TS 3 you can find an XLR jack DMX Out and an XLR plug DMX In which can be used for connecting several devices Choose...

Page 6: ...r to connect the controller with the fixture or one fixture with another Occupation of the XLR connection If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the DMX chain If you wish to connect DMX controllers with other XLR outputs you need to use adapter cables Building a serial DMX chain Connect ...

Page 7: ...nnected to dimming packs OPERATION After you connected the effect to the mains the TS 3 starts running During the Reset the motors are trimmed and the device is ready for use within approximately 20 seconds Sound control Master Slave operation The lamp is automatically ignited as soon as the condensor microphone receives music signals If the projector does not react to the music signals the microp...

Page 8: ... movement Tilt within 90 Push slider up in order to move the mirror vertically TILT Gradual mirror adjustment from one end of the slider to the other 0 255 128 center The mirror can be stopped at any position you wish Control channel 3 Colour wheel Linear colour change following the movement of the slider In this way you can stop the colour wheel in any position DMX value Feature 0 15 White 16 31 ...

Page 9: ...stall the new fuse in the fuseholder Step 4 Replace the fuseholder in the housing and fix it The lens has to be replaced when it is obviously damaged so that its function is impaired e g due to cracks or deep scratches CAUTION Should you need any spare parts please use genuine parts Should you have further questions please contact your dealer TECHNICAL SPECIFICATIONS Power supply 230 V 50 Hz Power...