00047090.DOC, Version 1.0
19/22
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the effect to the mains, the STP-10 für 10x GU-10 DMX starts running.
With the POWER-switch, you can switch the device on and off.
The STP-10 features a memory function. The last program selected will begin anew when the device is
restarted.
Setting the operation mode
Press the MODE button to select the desired operating mode via display. Via the UP and DOWN buttons, the
values for speed, dimmer as well as internal programs and the DMX addresses can be set. Please see the
following graphic for the operating modes.
MODE
MODE
OPERATION
OPERATION
DISPLAY
DISPLAY
Display on
Display auto off
10 Channel
Occupation
11 Channel
Occupation
12 Channel
Occupation
Slave
Internal Programs
Speed
Total Dimmer
Sound Control
0001
0002
1xxx
(xxx=DMX address)
2xxx
(xxx=DMX address)
3xxx
(xxx=DMX address)
4***
5***
(*** = Program number)
6***
(*** = Speed value)
7***
(*** = Dimmer value)
8***
(*** = Sensitivity)
Display illumination steady on
Display illumination switches of automatically after 10
seconds
CH1 = Channel 1 Dimmer...CH10 = Channel 10 Dimmer
CH1 = Channel 1 Dimmer...CH10 = Channel 10 Dimmer,
CH11 = Total Dimmer
CH1 = Channel 1 Dimmer...CH10 = Channel 10 Dimmer,
CH11 = Total Dimmer,
CH12 = Strobe
Slave operation
10 internal programs to choose from
16 speed steps
Intensity adjustable from 0 to 255 with the UP / DOWN
buttons
Automatically jumps from one level to the next in an endless
loop, depending upon music intensity
Please note:
The display should not be on for longer than 2 minutes, as this would interfere with the proper
functioning of the device.