00042053.DOC, Version 1.0
30/31
Operation via DIP-switches
0=OFF 1=ON X=0FF or ON
DIPSWITCH CHART
FUNCTION
1 2 3 4 5 6 7 8 9 10
X X X X X X X X X 1 AUTO MODE
X X X X X X X X 1 1 Sound Active
SET DMX
ADDRESS
0
DMX MODE
Sound-active mode:
DIP1
OFF ON
OFF ON
OFF ON
OFF ON
DIP2
OFF OFF ON
ON
OFF OFF ON
ON
DIP3
OFF OFF OFF OFF ON
ON
ON
ON
PAGE
1
2
3
4
5
6
7
8
DMX-controlled operation
You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
DMX-protocol
DMX
Channel
Function
DMX512
data
Description
CH1
enabling
0 255 Above 32 enable DMX controller
CH2
Page Selection
0 255 9 Page
CH3
Image Selection
0 255 N static/moving images with numbers of
average distribution.
CH4
Speed
0 255
scanning
speed
CH5
Fade out
0 255
project only above 53
CH6
Zoom
0 255
0 for the minimum, 255 for the
maximum.
CH7
x size
0 255
Adjust the horizontal
rotation
CH8
Y size
0 255
Adjust the vertical ratation
CH9
Spinning
0 255
The overal pattern spinning
CH10
X position
0 255
Adjust the horizontal
position
CH11
Y position
0 255
Adjust the vertical position
7. CLEANING AND MAINTENANCE
Laser products in discotheques are technical working installations and fall under the Equipment Safety Act.
This is why they must fulfill its requirements.
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection: