background image

41907172_V_1_1.DOC

12/31

Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.

This device falls under protection-class I. The power plug must only be plugged into a protection class I
outlet. The voltage and frequency must exactly be the same as stated on the device. Wrong voltages or
power outlets can lead to the destruction of the device and to mortal electrical shock.

Always plug in the power plug last. The power plug must always be inserted without force. Make sure that
the plug is tightly connected with the outlet.

Never let the power-cord come into contact with other cables! Handle the power-cord and all connections
with the mains with particular caution! Never touch them with wet hands, as this could lead to mortal
electrical shock.

Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock.

The cable insert or the female part in the device must never be strained. There must always be sufficient
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage.

Make sure that the power-cord is never crimped or damaged by sharp edges. Check the device and the
power-cord from time to time.

If extension cords are used, make sure that the core diameter is sufficient for the required power
consumption of the device. All warnings concerning the power cords are also valid for possible extension
cords.

Always disconnect from the mains, when the device is not in use or before cleaning it. Only handle the
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the
device must be disconnected via the mains.

If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be
cleaned with a dry cloth. Dust can reduce the insulation which may lead to mortal electrical shock. More
severe dirt in and at the device should only be removed by a specialist.

There must never enter any liquid into power outlets, extension cords or any holes in the housing of the
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately
be disconnected. This is also valid, if the device was exposed to high humidity. Also if the device is still
running, the device must be checked by a specialist if the liquid has reduced any insulation. Reduced
insulation can cause mortal electrical shock.

There must never be any objects entering into the device. This is especially valid for metal parts. If any metal
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries.

During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily
mean that the device is defective.

Caution:

 During the operation, the housing becomes very hot.

Do not switch the device on and off in short intervals as this would reduce the lamp’s life.

HEALTH HAZARD!

Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!

Keep away children and amateurs!

Summary of Contents for PRO FLOOD 4000 AC

Page 1: ...ibida toda reproducción Für weiteren Gebrauch aufbewahren Keep this manual for future needs Gardez ce mode d emploi pour des utilisations ultérieures Guarde este manual para posteriores usos BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI MANUAL DEL USUARIO PRO FLOOD 4000 AH AC Spot ...

Page 2: ...ECHNISCHE DATEN 10 INTRODUCTION 11 SAFETY INSTRUCTIONS 11 OPERATING DETERMINATIONS 13 INSTALLATION 14 Installing Replacing the lamps 14 Overhead rigging 14 Connection with the mains 16 OPERATION 16 CLEANING AND MAINTENANCE 16 TECHNICAL SPECIFICATIONS 17 INTRODUCTION 18 INSTRUCTIONS DE SÉCURITÉ 18 EMPLOI SELON LES PRESCRIPTIONS 20 INSTALLATION 21 Installer Remplacer des lampes 21 Montage par dessus...

Page 3: ...41907174 This user manual is valid for the article numbers 41907172 41907174 Ce mode d emploi est concu pour les n d art 41907172 41907174 Este manual del usuario es válido para las referencias 41907172 41907174 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under Vous pouvez trouvez la dernière version ...

Page 4: ...Freude an Ihrem Kauf haben werden Nehmen Sie den Scheinwerfer aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gefährlicher Netzspannung Bei die ser Spannung können Sie einen lebensgefährlichen elektrischen Schlag erhalten Dieses Gerät hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlose...

Page 5: ...gen Gerät bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Griffläche an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker beschädigt werden was zu tödlichen Stromschlägen führen kann Sind Stecker oder Geräteschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden W...

Page 6: ...Stromschlägen führen Beim Einsatz von Nebelgeräten ist zu beachten dass das Gerät nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelgerät entfernt betrieben wird Der Raum darf nur so stark mit Nebel gesättigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Gerät von direkter Sonneneinstr...

Page 7: ...echsel LEBENSGEFAHR Lampen nur bei ausgeschaltetem Gerät einsetzen Netzstecker ziehen Die Lampe muss gewechselt werden wenn diese beschädigt ist oder sich durch Wärme verformt hat ACHTUNG Vor dem Wechseln der Lampe das Gerät allpolig von der Netzspannung trennen Netzstecker ziehen und die Lampe unbedingt erst abkühlen lassen ca 5 Minuten Vermeiden Sie es den Glaskörper mit bloßen Händen zu berühre...

Page 8: ...nhaltet aber beschränkt sich nicht allein auf Berechnungen zur Definition der Tragfähigkeit verwendetes Installations material und regelmäßige Sicherheitsinspektionen des verwendeten Materials und des Gerätes Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht über eine solche Qualifikation verfügen sondern beauftragen Sie einen professionellen Installateur Unsachgemäße Instal...

Page 9: ...ne Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein BEDIENUNG Wenn Sie das Gerät an die Spannungsversorgung angeschlossen haben nimmt der Pro Flood den Betrieb auf REINIGUNG UND WARTUNG Der Unternehmer hat dafür zu sorgen dass sicherheitste...

Page 10: ...satzteile benötigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Gerätes beschädigt wird muss sie durch den autorisierten Fachhandel ersetzt werden um Gefährdungen zu vermeiden Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachhändler jederzeit gerne zur Verfügung TECHNISCHE DATEN Version 41907172 4000 AH 41907174 4000 AC Spannungsversorgung 230 V AC 5...

Page 11: ...ons given in this manual we are sure that you will enjoy this device for a long period of time Unpack your spot SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it i...

Page 12: ...e mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out o...

Page 13: ... over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms The symbol m determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 2 meters This device is only allowed for an installation via the mounting bracket In order to safeguard suf...

Page 14: ... Procedure Step 1 Remove the color filter frame Step 2 Unlock the protective grid and open it Step 3 If replacing the lamp remove the old pole burner from the lamp socket Step 4 Insert the new pole burner into the lamp socket Step 5 Close the protective grid and close the lock Do not operate this device with opened protective grid Overhead rigging The installation of the device has to be built and...

Page 15: ...l be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freely in the room Caution Devices in hanging installations may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the device Before rigging make sure that the installation area can hold a minimum...

Page 16: ...ty relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The elec...

Page 17: ... AC Power supply 230 V AC 50 Hz 230 V AC 50 Hz Power consumption max 4000 W max 4000 W Dimensions LxWxH 1111 x 300 x 310 mm 640 x 610 x 230 mm Weight 12 kg 12 kg Fitting lamps No Art Nr OMNILUX 230V 750W R7s 189mm pole burner 91200000 91200000 OMNILUX 230V 1000W R7s 189mm pole burner 91200010 91200010 Maximum ambient temperature Ta 45 C 45 C Maximum housing temperature TB steady state 225 C 225 C ...

Page 18: ...remercions d avoir choisi un EUROLITE Pro Flood projecteur Si vous respectez les instructions de service suivantes vous allez profiter longtemps de votre achat Sortez le projecteur de son emballage INSTRUCTIONS DE SÉCURITÉ ATTENTION Soyez prudent lors de manipulations électriques avec une tension dangereuse vous êtes soumis à des risques d électrocution Cet appareil a quitté les ateliers dans un é...

Page 19: ...ées Débranchez l appareil lorsque vous ne l utilisez pas et avant de le nettoyer Pour ce faire utilisez les surfaces de maintien sur la fiche ne tirez jamais le câble secteur Sinon le câble et la fiche peuvent être endommagées ce qui peut mener à des électrocutions mortelles Si la fiche ou l interrupteur de l appareil ne sont pas accessibles par exemple parce qu ils sont enfermés par d autres pièc...

Page 20: ... Lors de l utilisation de machines à fumée il faut faire attention à ce que l appareil ne soit jamais exposé directement au jet de fumée et qu il soit mis en service au moins à 0 5 m de distance d une machine de fumée L espace doit être saturé de fumée seulement aussi fort de sorte qu il a ait encore une bonne vue d au moins 10 m Il faut que la température ambiante soit entre 5 C et 45 C Ne pas ex...

Page 21: ...ampe chute etc INSTALLATION Installer Remplacer des lampes DANGER DE MORT Toujours mettre hors tension avant de mettre en place les lampes Débrancher avant toute manipulation La lampe doit être remplacée lorsqu elle a été endommagée ou déformée par la chaleur ATTENTION Avant le remplacement de l ampoule toujours laisser refroidir env 5 minutes celle ci et débrancher l appareil Ne jamais manipuler ...

Page 22: ...es IMPORTANT LE MONTAGE PAR DESSUS DE LA TETE EXIGE UN HAUT NIVEAU D EXPERIENCE Ceci comprend mais n est pas limitée seulement des calculs pour la définition de la capacité de charge le matériel d installation utilisé et des inspections de sécurité régulières du matériel utilisé et du l appareil N essayez jamais de procéder à une installation vous même si vous ne disposez pas d une telle qualifica...

Page 23: ...r à courant de défaut RCD avec un courant différentiel résiduel de 30 mA MANIEMENT Le Pro Flood commençera à fonctionner dès que vous le brancherez au secteur NETTOYAGE ET MAINTENANCE L entrepreneur doit s assurer que les installations concernant la sécurité technique et la sécurité des machines soient examinées au moins tous les quatre ans par un expert au cadre de l épreuve de réception L entrep...

Page 24: ...ge sont nécéssaires toujours utiliser des pièces d origine Quand le câble secteur de cet appareil est endommagé il doit être remplacé par un installateur agrée pour éviter des dangers Pour tout renseignement complémentaire votre revendeur se tient à votre entière disposition CARACTÉRISTIQUES TECHNIQUES Version 41907172 4000 AH 41907174 4000 AC Alimentation 230 V AC 50 Hz 230 V AC 50 Hz Puissance d...

Page 25: ...s que vaya a gozarse mucho de su compra Desembale su proyector INSTRUCCIONES DE SEGURIDAD Tenga cuidado cuando opere con este aparato Con un voltaje peligroso puede sufrir una peligrosa descarga eléctrica al tocar los cables PRECAUCIÓN Este aparato ha salido de nuestro establecimiento en absolutas perfectas condiciones Para mantener esta condición y asegurar un manejo seguro es absolutamente neces...

Page 26: ... red Desconecte el aparato de la red cuando hay polvo en la clavija u el aparato Limpie el aparato con un paño suave y húmedo Polvo puede reducir la insulación que puede causar un golpe electríco mortal Poluciones mas graves deben ser removidos por un especialista Líquido de todas formas deben nunca entrar en enchufes conectores u algunos orificios del aparato Cuando supone que líquido puede haber...

Page 27: ...tos iluminados La distancia entre la salida de luz y el área iluminado no debe ser menos de 2 metros Este aparato ha sido diseñado sólo para la instalación mediante la lira de montaje Para garantizar una bien ventilación Vd debe respectar un espacio de 50 cm en torno al aparato El aparato nunca debe tocar objetos o superficies en el ambiente Durante el montaje del proyector el desmontaje y operaci...

Page 28: ...a la instalación Procedimiento Paso 1 Quite el portafiltros Paso 2 Abre la rejilla de protección Paso 3 Cuando quire reemplazar una halógena lineal defectuosa primero quite la del casquillo Paso 4 Coloque la halógena lineal en el casquillo Paso 5 Cierre la rejilla de protección No maneje este aparato con la rejilla de protección abierta Montaje por encima de la cabeza La suspensión del aparato deb...

Page 29: ...adores altos siempre debe utilisar sistemas de trussing El aparato nunca debe ser instalado pendiendo libremente en el espacio Atención En caso de caída aparatos montados por encima de la cabeza pueden causar daños cuantiosos Cuando tiene dudas en la seguridad de una forma de instalación NO instale el aparato Asegúrese antes de la montaje que el área de montaje puede llevar una carga de punto de u...

Page 30: ... deben ser observados 1 Todos tornillos con cuales el aparato o partes del aparato están montado deben ser atornillados fijamente y no deben ser corroídos 2 No debe haber deformaciones en la caja fijaciones y el sitio de instalación techo abajamiento trussing 3 Los cables de conexión eléctricos no deben haber deterioraciónes fatiga de material por ejemplo cables porosos o depósitos Otras instrucci...

Page 31: ...30 V AC 50 Hz 230 V AC 50 Hz Consumo max 4000 W max 4000 W Dimensiones La xAn xAl 1111 x 300 x 310 mm 640 x 610 x 230 mm Peso 12 kg 12 kg Lámpara Referencia Referencia OMNILUX 230V 750W R7s 189mm halógena lineal 91200000 91200000 OMNILUX 230V 1000W R7s 189mm halógena lineal 91200010 91200010 Máxima temperatura ambiente Ta 45 C 45 C Máxima temperatura de la casa inercia TB 225 C 225 C Nota Todas la...