background image

41907172_V_1_1.DOC

16/31

Connection with the mains

Connect the device to the mains with the power-plugs.

The occupation of the connection-cables is as follows:

Cable

Pin

International

Brown

Live

L

Blue

Neutral

N

Yellow/Green

Earth

The earth has to be connected!

If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.

The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

OPERATION

After you connected the effect to the mains, the Pro Flood starts running.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.

The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.

The following points have to be considered during the inspection:
1)  All screws used for installing the devices or parts of the device have to be tighly connected and must not

be corroded.

2)  There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,

trussing).

3)  The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or

sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.

Disconnect from mains before starting maintenance operation!

DANGER TO LIFE!

We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!

The interior of the device should be cleaned at least annually using a vacuum-cleaner or an air-jet.

There are no serviceable parts inside the device except for the lamp. Maintenance and service operations
are only to be carried out by authorized dealers.

Please refer to the instructions under "Installing/Replacing the lamp".

Should you need any spare parts, please use genuine parts.

Summary of Contents for PRO FLOOD 4000 AC

Page 1: ...ibida toda reproducción Für weiteren Gebrauch aufbewahren Keep this manual for future needs Gardez ce mode d emploi pour des utilisations ultérieures Guarde este manual para posteriores usos BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI MANUAL DEL USUARIO PRO FLOOD 4000 AH AC Spot ...

Page 2: ...ECHNISCHE DATEN 10 INTRODUCTION 11 SAFETY INSTRUCTIONS 11 OPERATING DETERMINATIONS 13 INSTALLATION 14 Installing Replacing the lamps 14 Overhead rigging 14 Connection with the mains 16 OPERATION 16 CLEANING AND MAINTENANCE 16 TECHNICAL SPECIFICATIONS 17 INTRODUCTION 18 INSTRUCTIONS DE SÉCURITÉ 18 EMPLOI SELON LES PRESCRIPTIONS 20 INSTALLATION 21 Installer Remplacer des lampes 21 Montage par dessus...

Page 3: ...41907174 This user manual is valid for the article numbers 41907172 41907174 Ce mode d emploi est concu pour les n d art 41907172 41907174 Este manual del usuario es válido para las referencias 41907172 41907174 Das neueste Update dieser Bedienungsanleitung finden Sie im Internet unter You can find the latest update of this user manual in the Internet under Vous pouvez trouvez la dernière version ...

Page 4: ...Freude an Ihrem Kauf haben werden Nehmen Sie den Scheinwerfer aus der Verpackung SICHERHEITSHINWEISE ACHTUNG Seien Sie besonders vorsichtig beim Umgang mit gefährlicher Netzspannung Bei die ser Spannung können Sie einen lebensgefährlichen elektrischen Schlag erhalten Dieses Gerät hat das Werk in sicherheitstechnisch einwandfreiem Zustand verlassen Um diesen Zustand zu erhalten und einen gefahrlose...

Page 5: ...gen Gerät bei Nichtbenutzung und vor jeder Reinigung vom Netz trennen Fassen Sie dazu den Netzstecker an der Griffläche an und ziehen Sie niemals an der Netzleitung Ansonsten kann das Kabel und der Stecker beschädigt werden was zu tödlichen Stromschlägen führen kann Sind Stecker oder Geräteschalter z B durch Einbau nicht erreichbar so muss netzseitig eine allpolige Abschaltung vorgenommen werden W...

Page 6: ...Stromschlägen führen Beim Einsatz von Nebelgeräten ist zu beachten dass das Gerät nie direkt dem Nebelstrahl ausgesetzt ist und mindestens 0 5 m von einem Nebelgerät entfernt betrieben wird Der Raum darf nur so stark mit Nebel gesättigt sein dass eine gute Sichtweite von mindestens 10 m besteht Die Umgebungstemperatur muss zwischen 5 C und 45 C liegen Halten Sie das Gerät von direkter Sonneneinstr...

Page 7: ...echsel LEBENSGEFAHR Lampen nur bei ausgeschaltetem Gerät einsetzen Netzstecker ziehen Die Lampe muss gewechselt werden wenn diese beschädigt ist oder sich durch Wärme verformt hat ACHTUNG Vor dem Wechseln der Lampe das Gerät allpolig von der Netzspannung trennen Netzstecker ziehen und die Lampe unbedingt erst abkühlen lassen ca 5 Minuten Vermeiden Sie es den Glaskörper mit bloßen Händen zu berühre...

Page 8: ...nhaltet aber beschränkt sich nicht allein auf Berechnungen zur Definition der Tragfähigkeit verwendetes Installations material und regelmäßige Sicherheitsinspektionen des verwendeten Materials und des Gerätes Versuchen Sie niemals die Installation selbst vorzunehmen wenn Sie nicht über eine solche Qualifikation verfügen sondern beauftragen Sie einen professionellen Installateur Unsachgemäße Instal...

Page 9: ...ne Elektroinstallation angeschlossen werden die den VDE Bestimmungen DIN VDE 0100 entspricht Die Hausinstallation muss mit einem Fehlerstromschutzschalter RCD mit 30 mA Bemessungsdifferenzstrom ausgestattet sein BEDIENUNG Wenn Sie das Gerät an die Spannungsversorgung angeschlossen haben nimmt der Pro Flood den Betrieb auf REINIGUNG UND WARTUNG Der Unternehmer hat dafür zu sorgen dass sicherheitste...

Page 10: ...satzteile benötigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung dieses Gerätes beschädigt wird muss sie durch den autorisierten Fachhandel ersetzt werden um Gefährdungen zu vermeiden Sollten Sie noch weitere Fragen haben steht Ihnen Ihr Fachhändler jederzeit gerne zur Verfügung TECHNISCHE DATEN Version 41907172 4000 AH 41907174 4000 AC Spannungsversorgung 230 V AC 5...

Page 11: ...ons given in this manual we are sure that you will enjoy this device for a long period of time Unpack your spot SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it i...

Page 12: ...e mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken out o...

Page 13: ... over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms The symbol m determines the minimum distance from lighted objects The minimum distance between light output and the illuminated surface must be more than 2 meters This device is only allowed for an installation via the mounting bracket In order to safeguard suf...

Page 14: ... Procedure Step 1 Remove the color filter frame Step 2 Unlock the protective grid and open it Step 3 If replacing the lamp remove the old pole burner from the lamp socket Step 4 Insert the new pole burner into the lamp socket Step 5 Close the protective grid and close the lock Do not operate this device with opened protective grid Overhead rigging The installation of the device has to be built and...

Page 15: ...l be lowered from the ceiling or high joists professional trussing systems have to be used The device must never be fixed swinging freely in the room Caution Devices in hanging installations may cause severe injuries when crashing down If you have doubts concerning the safety of a possible installation do NOT install the device Before rigging make sure that the installation area can hold a minimum...

Page 16: ...ty relating and machine technical installations are inspected by a skilled person once a year The following points have to be considered during the inspection 1 All screws used for installing the devices or parts of the device have to be tighly connected and must not be corroded 2 There must not be any deformations on housings fixations and installation spots ceiling suspension trussing 3 The elec...

Page 17: ... AC Power supply 230 V AC 50 Hz 230 V AC 50 Hz Power consumption max 4000 W max 4000 W Dimensions LxWxH 1111 x 300 x 310 mm 640 x 610 x 230 mm Weight 12 kg 12 kg Fitting lamps No Art Nr OMNILUX 230V 750W R7s 189mm pole burner 91200000 91200000 OMNILUX 230V 1000W R7s 189mm pole burner 91200010 91200010 Maximum ambient temperature Ta 45 C 45 C Maximum housing temperature TB steady state 225 C 225 C ...

Page 18: ...remercions d avoir choisi un EUROLITE Pro Flood projecteur Si vous respectez les instructions de service suivantes vous allez profiter longtemps de votre achat Sortez le projecteur de son emballage INSTRUCTIONS DE SÉCURITÉ ATTENTION Soyez prudent lors de manipulations électriques avec une tension dangereuse vous êtes soumis à des risques d électrocution Cet appareil a quitté les ateliers dans un é...

Page 19: ...ées Débranchez l appareil lorsque vous ne l utilisez pas et avant de le nettoyer Pour ce faire utilisez les surfaces de maintien sur la fiche ne tirez jamais le câble secteur Sinon le câble et la fiche peuvent être endommagées ce qui peut mener à des électrocutions mortelles Si la fiche ou l interrupteur de l appareil ne sont pas accessibles par exemple parce qu ils sont enfermés par d autres pièc...

Page 20: ... Lors de l utilisation de machines à fumée il faut faire attention à ce que l appareil ne soit jamais exposé directement au jet de fumée et qu il soit mis en service au moins à 0 5 m de distance d une machine de fumée L espace doit être saturé de fumée seulement aussi fort de sorte qu il a ait encore une bonne vue d au moins 10 m Il faut que la température ambiante soit entre 5 C et 45 C Ne pas ex...

Page 21: ...ampe chute etc INSTALLATION Installer Remplacer des lampes DANGER DE MORT Toujours mettre hors tension avant de mettre en place les lampes Débrancher avant toute manipulation La lampe doit être remplacée lorsqu elle a été endommagée ou déformée par la chaleur ATTENTION Avant le remplacement de l ampoule toujours laisser refroidir env 5 minutes celle ci et débrancher l appareil Ne jamais manipuler ...

Page 22: ...es IMPORTANT LE MONTAGE PAR DESSUS DE LA TETE EXIGE UN HAUT NIVEAU D EXPERIENCE Ceci comprend mais n est pas limitée seulement des calculs pour la définition de la capacité de charge le matériel d installation utilisé et des inspections de sécurité régulières du matériel utilisé et du l appareil N essayez jamais de procéder à une installation vous même si vous ne disposez pas d une telle qualifica...

Page 23: ...r à courant de défaut RCD avec un courant différentiel résiduel de 30 mA MANIEMENT Le Pro Flood commençera à fonctionner dès que vous le brancherez au secteur NETTOYAGE ET MAINTENANCE L entrepreneur doit s assurer que les installations concernant la sécurité technique et la sécurité des machines soient examinées au moins tous les quatre ans par un expert au cadre de l épreuve de réception L entrep...

Page 24: ...ge sont nécéssaires toujours utiliser des pièces d origine Quand le câble secteur de cet appareil est endommagé il doit être remplacé par un installateur agrée pour éviter des dangers Pour tout renseignement complémentaire votre revendeur se tient à votre entière disposition CARACTÉRISTIQUES TECHNIQUES Version 41907172 4000 AH 41907174 4000 AC Alimentation 230 V AC 50 Hz 230 V AC 50 Hz Puissance d...

Page 25: ...s que vaya a gozarse mucho de su compra Desembale su proyector INSTRUCCIONES DE SEGURIDAD Tenga cuidado cuando opere con este aparato Con un voltaje peligroso puede sufrir una peligrosa descarga eléctrica al tocar los cables PRECAUCIÓN Este aparato ha salido de nuestro establecimiento en absolutas perfectas condiciones Para mantener esta condición y asegurar un manejo seguro es absolutamente neces...

Page 26: ... red Desconecte el aparato de la red cuando hay polvo en la clavija u el aparato Limpie el aparato con un paño suave y húmedo Polvo puede reducir la insulación que puede causar un golpe electríco mortal Poluciones mas graves deben ser removidos por un especialista Líquido de todas formas deben nunca entrar en enchufes conectores u algunos orificios del aparato Cuando supone que líquido puede haber...

Page 27: ...tos iluminados La distancia entre la salida de luz y el área iluminado no debe ser menos de 2 metros Este aparato ha sido diseñado sólo para la instalación mediante la lira de montaje Para garantizar una bien ventilación Vd debe respectar un espacio de 50 cm en torno al aparato El aparato nunca debe tocar objetos o superficies en el ambiente Durante el montaje del proyector el desmontaje y operaci...

Page 28: ...a la instalación Procedimiento Paso 1 Quite el portafiltros Paso 2 Abre la rejilla de protección Paso 3 Cuando quire reemplazar una halógena lineal defectuosa primero quite la del casquillo Paso 4 Coloque la halógena lineal en el casquillo Paso 5 Cierre la rejilla de protección No maneje este aparato con la rejilla de protección abierta Montaje por encima de la cabeza La suspensión del aparato deb...

Page 29: ...adores altos siempre debe utilisar sistemas de trussing El aparato nunca debe ser instalado pendiendo libremente en el espacio Atención En caso de caída aparatos montados por encima de la cabeza pueden causar daños cuantiosos Cuando tiene dudas en la seguridad de una forma de instalación NO instale el aparato Asegúrese antes de la montaje que el área de montaje puede llevar una carga de punto de u...

Page 30: ... deben ser observados 1 Todos tornillos con cuales el aparato o partes del aparato están montado deben ser atornillados fijamente y no deben ser corroídos 2 No debe haber deformaciones en la caja fijaciones y el sitio de instalación techo abajamiento trussing 3 Los cables de conexión eléctricos no deben haber deterioraciónes fatiga de material por ejemplo cables porosos o depósitos Otras instrucci...

Page 31: ...30 V AC 50 Hz 230 V AC 50 Hz Consumo max 4000 W max 4000 W Dimensiones La xAn xAl 1111 x 300 x 310 mm 640 x 610 x 230 mm Peso 12 kg 12 kg Lámpara Referencia Referencia OMNILUX 230V 750W R7s 189mm halógena lineal 91200000 91200000 OMNILUX 230V 1000W R7s 189mm halógena lineal 91200010 91200010 Máxima temperatura ambiente Ta 45 C 45 C Máxima temperatura de la casa inercia TB 225 C 225 C Nota Todas la...