00042289.DOC, Version 1.0
19/28
DESCRIPTION
Features
LED RGB Outdoor Blinder with 1 W LEDs
• Equipped with 4 x 36 x 1 W LEDs: 12 x red, 12 x green, 12 x blue
• 3, 5, 8 or 15 DMX channels selectable for numerous applications
• Stepless RGB colour changing
• Programmable color-change speed and strobe effect
• Masterdimmer
• Strobe effect
• 7 color presets and 1 built-in program (can be edited)
• DMX-controlled operation or stand alone operation with Master/Slave-function
• Suitable for external use, IP 65
• For architectural lighting or large stage backgrounds
• Perfect for public places and buildings
• Locking possibility at the mounting bracket
• Pure convection cooling via cooling ribs, no fans
• Advantages of LED-technology: extremely long life of the LEDs, low power consumption, minimal heat
emission, defacto maintenance free with brilliant light radiation
• Addressing via control panel with 4-digit LED display
• Control via display module or any regular 512-DMX-controller
• Feed-through output allows to power another device
• After every 8 devices the fixtures must have a renewed connection with the power mains
INSTALLATION
Fixing several LED EXT-Blinders:
Please use the fixing elements in the metal frame to fix side-by-side mounted LED EXT-Blinders. For this
purpose, each LED EXT-Blinder features a fixing element at each side of the frame in order to fix several
LED EXT-Blinders.
Overhead rigging
DANGER TO LIFE!
Please consider the EN 60598-2-17and the respective national standards during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the projector has to be built and constructed in a way that it can hold 10 times the weight
for 1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the fixture staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.