00027443.DOC, Verison 1.1
19/37
Addressing
Each device occupies 1 channel. To ensure that the control signals are properly directed to each device, the
device requires adressing. This is to be done for every single device by changing the DIP switches as set out
in this table.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you don’t have any overlapping channels in order to control each device correctly and
independently from any other device on the DMX data link. If two, three or more device are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Device 1 - channel 1
On
Off
Starting address
Device number
& channels
Off
Device 2 - channel 2
On
Off
Device 3 - channel 3
On
Off
Device 4 - channel 4
On
Off
Device 5 - channel 5
On
Off
1
2
4
8
16
32 64 128 256
DIP-switch no.
1
2
3
4
5
6
7
8
9
Setting the DMX-
starting address:
Controlling:
After having addressed all devices, you may now start operating these via your controller.
Important:
If start addresses are programmed via dip switches, then the remote control is de-activated.
DMX-protocol
Channel 1 – Fog volume
DMX-value:
Volume (%)
0
0
255
100
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues.