21
•
EN
MENU SETTINGS
Operating buttons
Button
Function
FUNCTION
Selecting menu items
UP
Setting values and options
DOWN
Setting values and options
TIMER
Timer mode activation
VOLUME
Continuous mode activation
MANUAL
Manual mode activation
Menu structure
Mode
Display
Function
Initiation
Welcome
This screen appears after switching on
Warm up phase
Warming Up
The machine is warming up and not ready for use
before the required operating temperature has been
reached.
Home screen
Ready To Fog
The warming up phase has been completed and the
device is now ready for use.
Operation settings
Interval Set
1-200s
Adjust time interval under timer mode
Duration Set
1-200s
Adjust duration under timer mode
Timer Out
1-100%
Adjust fog output volume under timer mode
Volume Out
1-100%
Adjust fog output volume under continuous mode
Nonstop Burst*
DMX settings
DMX512 Add.
001-512
Set DMX starting address
Fluid sensor
Fluid Sensor
on/off
Activate/deactivate fluid sensor
* Function not available