51701970_V_1_3.DOC
24/47
Control channel 4 - Adjusting the intervals (only in Timer-mode)
Data:
Time (second):
255
200
230-254
190
205-229
170
180-204
151
155-179
131
130-154
112
105-129
92
80-104
73
55-79
53
30-54
33
5-29
13
0
1
CLEANING AND MAINTENANCE
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a soft lint-free and moistened cloth. Never use
alcohol or solvents!
Clean the escape nozzle frequently from smoke fluid residues. Clean out debris with vinegar and a pipe
cleaner, making sure that the hole is free of clogs.
Cleaning the heating element
The heating element should regularly be cleaned every 30 operational hours in order to avoid clogging. Use
smoke-machine cleaner available at your dealer.
Procedure:
Fill cleaner into empty tank. Run the machine several times in a well-ventilated room only. The number of
repititions depends on the pollution level of the vaporizing elements. After use clean all remaining cleaner
and rinse the tank thoroughly with distilled water.
The EUROLITE smoke fluids we recommend are non-hazardous to the environment and can be disposed of
via the sewage system.
There are no servicable parts inside the device. Maintenance and service operations are only to be carried
out by authorized dealers.
If the fuse interrupts, please reset the breaker.
Should you need any spare parts, please use genuine parts.
If the power supply cable of this device will be damaged, it has to be replaced by authorized dealers only in
order to avoid hazards.