OPERATION
After connecting the device to the mains it is ready for operation. After switching on, the fans run at full
power for a short time. This is an intended cleaning function
.
The display indicates the last operating mode. The operating modes can be selected by means of the display
and the control buttons. All settings remain stored even if the device is disconnected from the mains. The
device can be operated in stand-alone mode via the control board or in DMX-controlled mode via any
commercial DMX controller.
Menu structure
Display
Function
Address
001-512
DMX address setting
Channel
4, 5, 7, 13, 15, 31
Setting DMX channel mode
DMX Monitor
CH:31
Manual setting of DMX values for each DMX Channel
CH:15
CH:13
CH:07
CH:05
CH:04
Auto
Auto 00 ~ Auto 36
Program 00 ~Program 36
(00 = continuously on)
Speed
000 - 255
Program running speed
slow > fast
Color
0 - 17
Setting the color/color effects of the
Auto program
Effect on Auto
Dimmer
000 - 255
Brightness dark > bright
Strobe
000 - 255
Strobe-Effect slow > fast
Mas Mode
Yes
Master - Slave
Master/Slave Function on
No
Master/Slave Function off
Manual
Dimmer
000 - 255
Brightness dark > bright
Strobe
000 - 255
Strobe-Effect slow > fast
Red
000 - 255
Intensity 0 – 100 %
Green
000 - 255
Intensity 0 – 100 %
Blue
000 - 255
Intensity 0 – 100 %
White
000 - 255
Intensity 0 – 100 %
Back L
(Display shutoff time)
On
Constantly on
60s
Off after 60 seconds
120s
Off after 120 seconds
300s
Off after 300 seconds
Temp
Temp 1
XXC°
Temperature of the LCD panel
Temp 2
XXC°
Inside temperature
Info
Test 1
Test 2
Reset
Yes / No
Restore factory settings
Version
Current software version
Dimmer curve
Curve 0
Linear
Dimmer curves
Curve 1
Square
Curve 2
InvSquare
Curve 3
S-curve
Fade time
Speed 0 ~ Speed 7