EuroLite LP-25 User Manual Download Page 7

00026479.DOC, Version 1.3

18/38

Please  note:

  for  overhead  rigging  in  public  or  industrial  areas,  a  series  of  safety  instructions  have  to  be

followed  that  this  manual  can  only  give  in  part.  The  operator  must  therefore  inform  himself  on  the  current
safety instructions and consider them.

The manufacturer cannot be made liable for damages caused by incorrect installations or insufficient safety
precautions!

Pull  the  safety  bond  through  the  attachment  eyelet  and  over  the  trussing  system  or  a  safe  fixation  spot.
Insert the end in the quick link and tighten the safety screw.

The maximum drop distance must never exceed 20 cm.

A safety bond which already held the strain of a crash or which is defective must not be used again.

Adjust the desired inclination-angle via the mounting-bracket and tighten the fixation screws.

DANGER TO LIFE!

Before taking into operation for the first time, the installation has to be approved by an expert!

Connection with the mains

Connect the device to the mains with the power-plug.

The occupation of the connection-cables is as follows:

Cable

Pin

International

Brown

Live

L

Blue

Neutral

N

Yellow/Green

Earth

The earth has to be connected!

If  the  device  will  be  directly  connected  with  the  local  power  supply  network,  a  disconnection  switch  with  a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.

The  device  must  only  be  connected  with  an  electric  installation  carried  out  in  compliance  with  the  IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.

Lighting effects must not be connected to dimming-packs.

OPERATION

After you connected the effect to the mains, the LP-25 starts running.

CLEANING AND MAINTENANCE

The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.

The  operator  has  to  make  sure  that  safety-relating  and  machine-technical  installations  are  inspected  by  a
skilled person once a year.

The following points have to be considered during the inspection:

Summary of Contents for LP-25

Page 1: ...ns given in this manual we are sure that you will enjoy this device for a long period of time Unpack your LP 25 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it i...

Page 2: ... the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken ou...

Page 3: ...mperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms Th...

Page 4: ...tee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc OVERVIEW 1 Lens 2 Focus lens adjustment 3 Lamp service lid 4 Focus light beam adjustment 5 Mounting bracket 6 Fixation screw 7 Attachment eyelet 8 Mounting bracket 9 Focus light beam adjustment 10 Attachment eyelet 11 Fixation screw 12 Power supply 13 Fuseholder ...

Page 5: ...op of the housing Step 2 Remove the service lid Step 3 If replacing the lamp remove the old lamp from the lamp socket Step 4 Insert the new EHJ 24 V 250 W GX 6 35 lamp into the lamp socket Step 5 Replace the service lid and tighten the screws Do not operate this device with opened service lid Inserting Exchanging gobos DANGER Install the gobos with the device switched off only Unplug from mains be...

Page 6: ...s may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation ca...

Page 7: ...e device to the mains with the power plug The occupation of the connection cables is as follows Cable Pin International Brown Live L Blue Neutral N Yellow Green Earth The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installatio...

Page 8: ...s smoke fluid tends to building up residues reducing the light output very quickly The cooling fan should be cleaned monthly The interior of the device should be cleaned at least annually using a vacuum cleaner or an air jet There are no serviceable parts inside the device except for the lamp and the fuse Maintenance and service operations are only to be carried out by authorized dealers Replacing...

Page 9: ...using temperature TB steady state 115 C Min distance from flammable surfaces 0 5 m Min distance to lighted object 0 5 m Fuse F 3 15 A 250 V Dimensions LxWxH 380 x 220 x 210 mm Weight 7 kg Fitting lamps No GE EHJ A1 223 24V 250W G 6 35 50h 88289000 OMNILUX EHJ 24V 250W G 6 35 50h 3000K 88289005 OSRAM EHJ 64655HLX A1 223 24V 250W G 6 35 88289010 OMNILUX EVC 24V 250W G 6 35 300h 88290005 Please note ...

Reviews: