background image

00026479.DOC, Version 1.3

13/38

Please make sure that there are no obvious transport damages. Should you notice any damages on the A/C
connection cable or on the casing, do not take the device into operation and immediately consult your local
dealer.

This  device  falls  under  protection-class  I.  The  power  plug  must  only  be  plugged  into  a  protection  class  I
outlet.  The  voltage  and  frequency  must  exactly  be  the  same  as  stated  on  the  device.  Wrong  voltages  or
power outlets can lead to the destruction of the device and to mortal electrical shock.

Always plug in the power plug last. The power plug must always be inserted without force. Make sure that
the plug is tightly connected with the outlet.

Never  let  the  power-cord  come  into  contact  with  other  cables!  Handle  the  power-cord  and  all  connections
with  the  mains  with  particular  caution!  Never  touch  them  with  wet  hands,  as  this  could  lead  to  mortal
electrical shock.

Never modify, bend, strain mechanically, put pressure on, pull or heat up the power cord. Never operate next
to sources of heat or cold. Disregard can lead to power cord damages, fire or mortal electrical shock.

The  cable  insert  or  the  female  part  in  the  device  must  never  be  strained.  There  must  always  be  sufficient
cable to the device. Otherwise, the cable may be damaged which may lead to mortal damage.

Make  sure  that  the  power-cord  is  never  crimped  or  damaged  by  sharp  edges.  Check  the  device  and  the
power-cord from time to time.

If  extension  cords  are  used,  make  sure  that  the  core  diameter  is  sufficient  for  the  required  power
consumption  of  the  device.  All  warnings  concerning  the  power  cords  are  also  valid  for  possible  extension
cords.

Always  disconnect  from  the  mains,  when  the  device  is  not  in  use  or  before  cleaning  it.  Only  handle  the
power-cord by the plug. Never pull out the plug by tugging the power-cord. Otherwise, the cable or plug can
be damaged leading to mortal electrical shock. If the power plug or the power switch is not accessible, the
device must be disconnected via the mains.

If the power plug or the device is dusty, the device must be taken out of operation, disconnected and then be
cleaned  with  a  dry  cloth.  Dust  can  reduce  the  insulation  which  may  lead  to  mortal  electrical  shock.  More
severe dirt in and at the device should only be removed by a specialist.

There  must  never  enter  any  liquid  into  power  outlets,  extension  cords  or  any  holes  in  the  housing  of  the
device. If you suppose that also a minimal amount of liquid may have entered the device, it must immediately
be  disconnected.  This  is  also  valid,  if  the  device  was  exposed  to  high  humidity.  Also  if  the  device  is  still
running,  the  device  must  be  checked  by  a  specialist  if  the  liquid  has  reduced  any  insulation.  Reduced
insulation can cause mortal electrical shock.

There must never be any objects entering into the device. This is especially valid for metal parts. If any metal
parts like staples or coarse metal chips enter into the device, the device must be taken out of operation and
disconnected immediately. Malfunction or short-circuits caused by metal parts may cause mortal injuries.

During the initial start-up some smoke or smell may arise. This is a normal process and does not necessarily
mean that the device is defective.

Caution:

 During the operation, the housing becomes very hot.

Do not switch the device on and off in short intervals as this would reduce the lamp’s life.

HEALTH HAZARD!

Never look directly into the light source, as sensitive persons may suffer an
epileptic shock (especially meant for epileptics)!

Keep away children and amateurs!

Summary of Contents for LP-25

Page 1: ...ns given in this manual we are sure that you will enjoy this device for a long period of time Unpack your LP 25 SAFETY INSTRUCTIONS CAUTION Be careful with your operations With a dangerous voltage you can suffer a dangerous electric shock when touching the wires This device has left our premises in absolutely perfect condition In order to maintain this condition and to ensure a safe operation it i...

Page 2: ... the mains when the device is not in use or before cleaning it Only handle the power cord by the plug Never pull out the plug by tugging the power cord Otherwise the cable or plug can be damaged leading to mortal electrical shock If the power plug or the power switch is not accessible the device must be disconnected via the mains If the power plug or the device is dusty the device must be taken ou...

Page 3: ...mperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 45 C This device must only be operated in an altitude between 20 and 2000 m over NN Never use the device during thunderstorms Over voltage could destroy the device Always disconnect the device during thunderstorms Th...

Page 4: ...tee becomes void Furthermore any other operation may lead to dangers like short circuit burns electric shock lamp explosion crash etc OVERVIEW 1 Lens 2 Focus lens adjustment 3 Lamp service lid 4 Focus light beam adjustment 5 Mounting bracket 6 Fixation screw 7 Attachment eyelet 8 Mounting bracket 9 Focus light beam adjustment 10 Attachment eyelet 11 Fixation screw 12 Power supply 13 Fuseholder ...

Page 5: ...op of the housing Step 2 Remove the service lid Step 3 If replacing the lamp remove the old lamp from the lamp socket Step 4 Insert the new EHJ 24 V 250 W GX 6 35 lamp into the lamp socket Step 5 Replace the service lid and tighten the screws Do not operate this device with opened service lid Inserting Exchanging gobos DANGER Install the gobos with the device switched off only Unplug from mains be...

Page 6: ...s may walk by or be seated IMPORTANT OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE including but not limited to calculating working load limits installation material being used and periodic safety inspection of all installation material and the device If you lack these qualifications do not attempt the installation yourself but instead use a professional structural rigger Improper installation ca...

Page 7: ...e device to the mains with the power plug The occupation of the connection cables is as follows Cable Pin International Brown Live L Blue Neutral N Yellow Green Earth The earth has to be connected If the device will be directly connected with the local power supply network a disconnection switch with a minimum opening of 3 mm at every pole has to be included in the permanent electrical installatio...

Page 8: ...s smoke fluid tends to building up residues reducing the light output very quickly The cooling fan should be cleaned monthly The interior of the device should be cleaned at least annually using a vacuum cleaner or an air jet There are no serviceable parts inside the device except for the lamp and the fuse Maintenance and service operations are only to be carried out by authorized dealers Replacing...

Page 9: ...using temperature TB steady state 115 C Min distance from flammable surfaces 0 5 m Min distance to lighted object 0 5 m Fuse F 3 15 A 250 V Dimensions LxWxH 380 x 220 x 210 mm Weight 7 kg Fitting lamps No GE EHJ A1 223 24V 250W G 6 35 50h 88289000 OMNILUX EHJ 24V 250W G 6 35 50h 3000K 88289005 OSRAM EHJ 64655HLX A1 223 24V 250W G 6 35 88289010 OMNILUX EVC 24V 250W G 6 35 300h 88290005 Please note ...