00037124.DOC, Version 1.2
16/22
OVERVIEW
Features:
Classical LED beam effect in RGB and white
Beams from the lenses perform circular movements and change the direction of movement with every bass
beat • DMX-512 control via regular DMX-controller (occupies 7 channels) • Sound-controlled via built-in
microphone • Microphone-sensitivity adjustable via rotary-control • Strobe effect • Auto mode • 9 internal
programs • Master/Slave function • Rugged compact housing in a beautiful design • Particularly bright
illuminating power of the 5mm RGB + white LEDs • Advantages of LED-technology: extremely long life of the
LEDs, low power consumption, minimal heat emission, defacto maintenance free with brilliant light radiation •
Ready for connection with power cord and safety-plug
INSTALLATION
Overhead rigging
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.
The installation must always be secured with a secondary safety attachment, e.g. an appropriate catch net.
This secondary safety attachment must be constructed in a way that no part of the installation can fall down
if the main attachment fails.
When rigging, derigging or servicing the device staying in the area below the installation place, on bridges,
under high working places and other endangered areas is forbidden.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert before taking into operation for the first time and after changes before taking into operation another
time.
The operator has to make sure that safety-relating and machine-technical installations are approved by an
expert after every four year in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are approved by a
skilled person once a year.
Procedure:
The device should be installed outside areas where persons may walk by or be seated.
IMPORTANT! OVERHEAD RIGGING REQUIRES EXTENSIVE EXPERIENCE, including (but not limited to)
calculating working load limits, installation material being used, and periodic safety inspection of all
installation material and the device. If you lack these qualifications, do not attempt the installation yourself,
but instead use a professional structural rigger. Improper installation can result in bodily injury and or
damage to property.
The device has to be installed out of the reach of people.
If the device shall be lowered from the ceiling or high joists, professional trussing systems have to be used.
The device must never be fixed swinging freely in the room.
Caution:
Devices in hanging installations may cause severe injuries when crashing down! If you have
doubts concerning the safety of a possible installation, do NOT install the device!