![EuroLite LED Z-200 TCL User Manual Download Page 21](http://html1.mh-extra.com/html/eurolite/led-z-200-tcl/led-z-200-tcl_user-manual_2438255021.webp)
00054293.DOC, Version 1.1
21/23
DMX-CONTROLLED OPERATION
You can control the devices individually via your DMX-controller. Every DMX-channel has a different
occupation with different features.
For DMX-controlled operation set DIP Switch 1 and 10 to ON. Also, set DIP Switch 1 and 10 to ON in order
to determine the Slave device.
Addressing
Each device occupies 6 channels. To ensure that the control signals are properly directed to each device,
the device requires addressing. This is to be adjusted for every single device by changing the DIP-switches
as set out in the table below.
The starting address is defined as the first channel from which the device will respond to the controller.
Please make sure that you do not have any overlapping channels in order to control each device correctly
and independently from any other fixture on the DMX data link. If two, three or more devices are addressed
similarly, they will work similarly.
Occupation of the DIP-switches:
Controlling:
After having addressed all LED Z-200 TCL, you may now start operating these via your lighting controller.
DMX-protocol
Control-channel 1 - Motor Rotation
Value
Feature
000 - 020
No rotation
021 - 170
Step by step counter clockwise rotation
171 - 255
Clockwise and counter clockwise rotation
Control-channel 2 - LED effects
Value
Feature
000 - 035
All LEDs on
036 - 070
Strobe-effect
071 - 105
Fade
106 - 140
Color-change
141 - 175
Color- strobe
176 - 210
Cross-fade
211 - 255
Cross-fade + strobe