51930310_V_1_0.DOC
24/28
control-channel 3
Mode
DMX-value
Characteristic
1-4
0-255
green
5-6
0-255
brightness
control-channel 4
Mode
DMX-value
Characteristic
1-4
0-255
blue
5
0-255
speed
control-channel 5
Mode
DMX-value
Characteristic
1-4
0-255
dimmer
control-channel 6
Mode
DMX-value
Characteristic
1-3
0-255
red
control-channel 7
Mode
DMX-value
Characteristic
1-3
0-255
green
control-channel 8
Mode
DMX-value
Characteristic
1-3
0-255
blue
ontrol-channel 9
Mode
DMX-value
Characteristic
1-3
0-255
dimmer
Mode
1
etc. until control-channel 33
2
etc. until control-channel 17
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Summary of Contents for LED WMB-830 RGB Bar