00072743.DOC, Version 1.0
24/26
DMX-protocol
DMX mode:
Press the MODE button until the display shows DMX MODE.
Press the ENTER button. You can select the desired DMX
address via the UP or DOWN buttons. Confirm your choice by
pressing ENTER.
3-Channel Mode (default setting)
Control-channel 1 – Dimmer
Value
Characteristic
000 - 255 Gradual adjustment of the dimmer intensity from 0 to 100 %
Control-channel 2 – Strobe
Value
Characteristic
000 - 255 No function
001 - 255 Strobe-effect with increasing speed
Control-channel 3 - Dimmer curves
Value
Characteristic
000 - 015 Control Board setting dimmer curve
016 - 045 Linear dimmer curve, response characteristics of halogen lamp
046 - 075 Square dimmer curve, response characteristics of halogen lamp
076 - 105
Inverse square dimmer curve, response characteristics of halogen
lamp
106 - 135 S-shaped dimmer curve, response characteristics of halogen lamp
136 - 165 Linear dimmer curve, response characteristics of LED
166 - 195 Square dimmer curve, response characteristics of LED
196 - 225 Inverse square dimmer curve, response characteristics of LED
226 - 255 S-shaped dimmer curve, response characteristics of LED
1-Channel Mode
Control-channel 1 – Dimmer
Value
Characteristic
000 - 255 Gradual adjustment of the dimmer intensity from 0 to 100 %
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).