00048513.DOC, Version 1.1
22/26
Caution:
At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120
resistor
between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture.
Master/Slave-Operation
The master/slave-operation enables that several devices can be synchronized and controlled by one master-
device.
On the rear panel of the EUROLITE LED PAR-64 RGBA, 10mm you can find an XLR-jack and an XLR-plug,
which can be used for connecting several devices.
Choose the device which is to control the effects. Set the desired Master-mode on the master-device. This
device then works as master-device and controls all other slave-devices, which are to be connected to the
master-device via a balanced microphone lead. Set the DMX start address 001 on every slave-device and
the DMX mode on your master device. For example, if the master-device is set on the 6 channel mode (6ch),
all slave-devices have to be set on the 6 channel mode as well. Connect the OUT-jack with the IN-plug of the
next device.
Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Lighting effects must not be connected to dimming-packs.
OPERATION
After you connected the spot to the mains, the EUROLITE LED PAR-64 RGBA, 10mm starts running.
The LED display lights up and you can choose the desired mode via the buttons MODE, UP and DOWN.
The device has two operating modes. It can be operated in Stand Alone or in DMX-controlled mode.
- STAND ALONE-MODE
•
Setting Solid Colors
•
Internal Programs, Sound Control
•
Setting Sound Sensitivity
- DMX MODE
Stand Alone-Mode
In the Stand Alone mode, the LED PAR-64 RGBA, 10mm can be used without controller.
Disconnect the LED PAR-64 RGBA, 10mm from the controller.