Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
Attention:
A booster must be installed after every eight LED tubes.
Connection of the devices
P1 = 2-pin socket
P2 = 2-pin plug
P3 = 120
Ω
. termination plug (end piece)
Attention:
The power supply must be interrupted between P1 and P2 every four tubes before and after the
booster. A booster must be installed after every eight LED tubes