20
5.2 Connections
Full ON
Stand by
GND
FOOT CONTROL
POWER SUPPLY
L
N
RECOMMEND
CIRCUIT BREAKER
TO APPARATUS
CONNECTION
5.2.1 Sound control
The sound signal is picked up via the integrated condensor microphone. This is why not extra connection to
the sound source is necessary.
5.2.2 Connection with the mains
Connect the device to the mains with the power-plug.
The occupation of the connection-cables is as follows:
Cable
Pin
International
Brown
Live
L
Blue
Neutral
N
Yellow/Green
Earth
The earth has to be connected!
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
5.2.3 Outputs
Output is via 4 safety sockets.
Connect your loads via the output-sockets. The maximum load per channel is 1,150 W (resistive). Please
note that the maximum current of 16 A must never be exceeded.
5.2.4 Footswitch
Connect your footswitch via the Start/Stop socket or the Standby socket on the rearpanel. In this way you
can stop the program-run.
5.2.5 DMX-512 connection
The wires must not come into contact with each other, otherwise
the fixtures will not work at all, or will not work properly.
Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with
the fixture or one fixture with another.