background image

 

The occupation of the connection-cables is as follows: 

 

Cable Pin 

International 

Brown Live 

Blue Neutral 

Yellow/Green Earth 

 

 
The earth has to be connected! 
 
If the device will be directly connected with the local power supply network, a disconnection switch with a 
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation. 
 
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum 
fault current of 30 mA. 
 

5.3 Connection with the dimmerpacks 

 

DMX-512: 

 

The wires must not come into contact with each other, otherwise 

the fixtures will not work at all, or will not work properly. 

Only use a stereo shielded cable and 3-pin XLR-plugs and connectors in order to connect the controller with 
the fixture or one fixture with another. 
 

Building a serial DMX-chain: 

Connect the DMX-output of the DPX-405 with the DMX-input of the nearest dimmerpack. Always connect 
one output with the input of the next fixture until all fixtures are connected. 
 

Caution: 

At the last fixture, the DMX-cable has to be terminated with a terminator. Solder a 120 

 resistor 

between Signal (–) and Signal (+) into a 3-pin XLR-plug and plug it in the DMX-output of the last fixture. 
 

5.4 Outputs 

Output is via 4 IEC-output-sockets on the rearpanel. 
 
Connect your loads via the output-sockets. The maximum load per channel is 1,150 W. Please note that the 
maximum current of 16 A must never be exceeded. 
 

6. OPERATION 

After you connected the device to the mains, the DPX-405 DMX is ready for use. 

 

The unit has two different operating modes. It can be used as a four channel chaser or as a 1, 2, or 4 
channel DMX dimmer pack. Please follow the instructions below to operate the unit in your desired mode. 

 

6.1 Chase Mode 

Use this operating mode only if you are planning on using your DPX-405 DMX as a four channel chaser. 
This device has 16 built in programs, you may select any of these programs or set the pack to chase in a 
random sequence of all 16 built-in programs for a more dramatic light show. You may control the speed at 
which the programs will chase. 
 
1)  Connect your spots to the terminal outputs. 
2)  Use the mode button to select chase mode: Chase mode is indicated by “P” followed by numbers 01-16. 

If “A” appears in the LCD display you are in DMX mode, “A” stands for address. 

70064110_V_1_0.DOC 

14/28

Summary of Contents for DPX-405 DMX

Page 1: ...da reproducci n F r weiteren Gebrauch aufbewahren Keep this manual for future needs Gardez ce mode d emploi pour des utilisations ult rieures Guarde este manual para posteriores usos BEDIENUNGSANLEITU...

Page 2: ...IONS DE SECURITE 17 3 EMPLOI SELON LES PRESCRIPTIONS 19 4 DESCRIPTION 19 5 SETUP 20 6 MANIEMENT 21 7 NETTOYAGE ET MAINTENANCE 21 8 CARACT RISTIQUES TECHNIQUES 22 1 INTRODUCCI N 23 2 INSTRUCCIONES DE S...

Page 3: ...n EUROLITE DPX 405 DMX entschieden haben Wenn Sie nachfolgende Hinweise beachten sind wir sicher dass Sie lange Zeit Freude an Ihrem Kauf haben werden Nehmen Sie den DPX 405 DMX aus der Verpackung 2 S...

Page 4: ...uf Besch digungen Werden Verl ngerungsleitungen verwendet muss sichergestellt werden dass der Adernquerschnitt f r die ben tigte Stromzufuhr des Ger tes zugelassen ist Alle Warnhinweise f r die Netzle...

Page 5: ...5 C und 45 C liegen Halten Sie das Ger t von direkter Sonneneinstrahlung auch beim Transport in geschlossenen W gen und Heizk rpern fern Die relative Luftfeuchte darf 50 bei einer Umgebungstemperatur...

Page 6: ...handeln an dem sich sowohl die Vorder als auch die R ckseite ffnen lassen Das Rackgeh use sollte mit einem L fter versehen sein Achten Sie bei der Standortwahl des Controllers darauf dass die warme L...

Page 7: ...zten Ger t muss die DMX Leitung durch einen Abschlusswiderstand abgeschlossen werden Dazu wird ein 120 Widerstand in einen XLR Stecker zwischen Signal und Signal eingel tet und in den DMX Ausgang am l...

Page 8: ...ern b jeweils die Kan le 1 und 2 und die Kan le 3 und 4 zu einer Gruppe anordnen Die erste Gruppe wird mit einem DMX Kanal gesteuert die zweite Gruppe wird von einem anderen DMX Kanal gesteuert Dadurc...

Page 9: ...ritt 4 Setzen Sie den Sicherungshalter wieder im Geh use ein und drehen Sie ihn fest Sollten einmal Ersatzteile ben tigt werden verwenden Sie bitte nur Originalersatzteile Wenn die Anschlussleitung di...

Page 10: ...net 1 INTRODUCTION Thank you for having chosen a EUROLITE DPX 405 DMX If you follow the instructions given in this manual we are sure that you will enjoy this device for a long period of time Unpack y...

Page 11: ...dges Check the device and the power cord from time to time If extension cords are used make sure that the core diameter is sufficient for the required power consumption of the device All warnings conc...

Page 12: ...The ambient temperature must always be between 5 C and 45 C Keep away from direct insulation particularly in cars and heaters The relative humidity must not exceed 50 with an ambient temperature of 4...

Page 13: ...lace with the exact same type fuse 8 Circuit breaker 16A Rearpanel 9 11 12 10 9 Power Output Four channel output 10 DMX Input This connector accepts your DMX input signal 11 DMX Output This connector...

Page 14: ...cted Caution At the last fixture the DMX cable has to be terminated with a terminator Solder a 120 resistor between Signal and Signal into a 3 pin XLR plug and plug it in the DMX output of the last fi...

Page 15: ...will be controlled by another DMX channel This gives the pack a DMX value of two 4 The default setting is a four channel DMX switcher each channel is controlled by one DMX channel 5 To change the cha...

Page 16: ...d by authorized dealers only in order to avoid hazards Should you have further questions please contact your dealer 8 TECHNICAL SPECIFICATIONS Power supply 230 V AC 50 Hz Max power output 3680 W Max c...

Page 17: ...nsmettre le mode d emploi un ventuel acheteur ou utilisateur de l appareil t l charger la version ult rieure du mode d emploi d Internet 1 INTRODUCTION Nous vous remercions d avoir choisi un EUROLITE...

Page 18: ...ur l alimentation en courant n cessaire pour l appareil Toutes les indications d avertissement pour le c ble secteur sont aussi valables pour des rallonges ventuellement utilis es D branchez l apparei...

Page 19: ...re 5 C et 45 C Ne pas exposer l appareil directement aux rayons solaires lors d un transport dans un v hicule ferm par exemple Lors d une temp rature ambiante de 45 C l humidit relative atmosph rique...

Page 20: ...5 1 Montage Installez l appareil sur une surface plane ou dans un rack Montage du rack Cet appareil est pr vu pour un 19 rack 483 mm Le rack devrait tre un mod le Double Door avec la possibilit d ouv...

Page 21: ...immerpack ainsi qu entre les appareils individuels doit tre effectu avec un c ble gain bipolare La connexion fiches est effectu e par une fiche XLR 3 p les et des couplages Connecter une cha ne DMX se...

Page 22: ...irez le fusible d fectueux du porte fusible Pas 3 Installez le nouveau fusible au porte fusible Pas 4 Remettez le porte fusible dans le bo tier et vissez le Si des pi ces de rechange sont n c ssaires...

Page 23: ...trica al tocar los cables PRECAUCI N Este aparato ha salido de nuestro establecimiento en absolutas perfectas condiciones Para mantener esta condici n y asegurar un manejo seguro es absolutamente nece...

Page 24: ...es conectores u algunos orificios del aparato Cuando supone que l quido puede haber entrado en el aparato desenchufe el aparato inmediatamente Tambi n cuando el aparato se ha encontrado en un ambiente...

Page 25: ...e transporte Por favor tenga en cuenta que por razones de seguridad las modificaciones no autorizadas del aparato est n prohibidas Cuando el aparato ser utilizado de un modo diferente como describido...

Page 26: ...aparato a la red mediante la clavija de alimentaci n La ocupaci n de los cables de conexi n es Cable Pin Internacional Marr n Fase L Azul Neutro N Amarillo Verde Tierra La tierra debe ser conectada Cu...

Page 27: ...antes de comenzar con el mantenimiento Recomendamos una limpieza frecuente del aparato Por favor utilice un pa o suave que no suelte pelusa humedecido No utilizar nunca alcohol o disolventes No hay pi...

Page 28: ...tencia m xima canal 1150 W Corriente m ximo canal 5 A Programas integrados 16 Casquillos de salida 4 enchufes CEI Fusible 4 x F 6 3 A 250 V Dimensiones LxPxA 482 x 163 x 44 mm Dimensi nes de montaje 1...