Never use the device during thunderstorms. Over voltage could destroy the device. Always disconnect the
device during thunderstorms.
The symbol
- - -m
determines the minimum distance from lighted objects. The minimum distance
between light-output and the illuminated surface must be more than 0.5 meters.
This device is only allowed for an installation via the mounting bracket. In order to safeguard sufficient
ventilation, leave 50 cm of free space around the device.
The housing must never touch surrounding surfaces or objects.
Make sure that the area below the installation place is blocked when rigging, derigging or servicing the
fixture.
Always fix the fixture with an appropriate safety-rope.
The maximum ambient temperature
T
a
= 25° C must never be exceeded.
Operate the device only after having become familiarized with its functions. Do not permit operation by
persons not qualified for operating the device. Most damages are the result of unprofessional operation!
Never use solvents or aggressive detergents in order to clean the device! Rather use a soft and damp cloth.
Please use the original packaging if the device is to be transported. Make sure that you pack the device in
the original state.
Please consider that unauthorized modifications on the device are forbidden due to safety reasons!
If this device will be operated in any way different to the one described in this manual, the product may suffer
damages and the guarantee becomes void. Furthermore, any other operation may lead to dangers like short-
circuit, burns, electric shock, lamp explosion, crash etc.
INSTALLATION
Installing/Replacing the lamp
DANGER TO LIFE!
Only install the lamp with the device switched off!
Unplug from mains before!
For the installation, you need one of the following lamps, depending upon device version:
GE HgV 125 UV-Lamp 125W E-27
89512000
OMNILUX UV-Lamp 125W E-27
89512005
GE HMV 160 UV-Lamp 230V/160W E-27
89513000
OMNILUX UV-Lamp 160W E-27
89513005
OMNILUX UV-Lamp 250W E-40
89513505
OMNILUX UV-Lamp 400W E-40
89514005
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).