![EuroLite 51914111 User Manual Download Page 26](http://html1.mh-extra.com/html/eurolite/51914111/51914111_user-manual_2438416026.webp)
00126414, Version 1.0
26/36
OPERATION
After connecting the device to the mains it is ready for operation. The display indicates the last operating
mode. The operating modes can be selected by means of the display and the control buttons. All settings
remain stored even if the device is disconnected from the mains. The device can be operated in stand-alone
mode via the control board or in DMX-controlled mode via any commercial DMX controller.
Control Board
The Control Board offers several features: you can simply set the starting address, run the pre-programmed
program or select a DMX channel mode.
Browse through the menu by pressing Menu. Press Enter in order to select the desired menu. You can
change the selection by pressing Up or Down. Press Enter in order to confirm. You can leave every mode by
pressing Menu. The functions provided are listed in the following sections.
Default settings shaded.
Menu
Sub menu
Description
STATIC
RED
000-255
Dimmer intensity of LED colors:
red, green, blue white, amber and UV
Strobe effect
0 – 20 (increasing)
GREE
000-255
BLUE
000-255
WHIT
000-255
A
000-255
UV
000-255
STRB
00-20
ADDRESS
001-512
DMX address setting
AUTO
AUTO
01-20
Automatic programs
Speed (increasing)
SP
00-99, 50
SOUND
01
Sound controlled program
(color change)
02
Sound controlled program
(strobe)
MODE
6CH/11CH/24CH/
41CH/77CH
Setting DMX channel mode/
number of DMX channels
SET
DIMCurve
DIMMER1-4
Dimmer curve
DIMMER1: Linear dimmer curve
DIMMER2: Exponential dimmer curve
DIMMER3: Inverse exponential dimmer curve
DIMMER4: S-curve
BACK
ON/OFF
Display shutoff
ON: Shuts off the display after about 60 seconds
OFF: Display is always on, does not switch off
DMXSate
ON/OFF
Mode when there is no DMX signal
ON: Holds the last signal when no DMX signal is
received
OFF: Switches off the LEDs when no DMX signal is
received
Sensor
000-100
Microphone sensitivity
Version
V.X.X
Software version
TEMP
XX°C
Temperature
inside of the device
RESET
Restore the factory settings
Interconnecting several devices (master/slave operation)
Several devices may be interconnected (max. 32). Then all slave units can be synchronized and controlled
with the master unit without the need for a DMX controller. The devices must be set to the corresponding
operating modes.
1
Configure all slave units before connecting the master unit: Set the start address 001 for all slave
devices.
2
Connect the DMX output of the master unit to the DMX input of the first slave unit. Then connect the
DMX output of the first slave unit to the DMX input of the second slave unit, etc. until all units have been
connected in a chain. Make sure the master unit is the first in the chain. Do not connect a DMX controller
to the DMX input of the master unit.
3
Set the master unit to the desired operating mode. The interconnected devices will now operate in sync.
Summary of Contents for 51914111
Page 1: ......