background image

©

 

EUROHEAT

 

DISTRIBUTORS (H.B.S) LTD.Aug 2006

       Instructions Part number IN1016 Ed G

1

Installation & Servicing

Harmony  5  and  Stanford  50  Gas 

Conventional Flue Stove

Serial Number

Part No.

Euroheat Distributors 

(H.B.S.) Ltd.,

Unit 2, Court Farm 

Business Park,

Bishops Frome,

Worcestershire,

WR6 5AY.

49991

EFEL

Summary of Contents for 49991

Page 1: ...ructions Part number IN1016 Ed G 1 Installation Servicing Harmony 5 and Stanford 50 Gas Conventional Flue Stove Serial Number Part No Euroheat Distributors H B S Ltd Unit 2 Court Farm Business Park Bi...

Page 2: ...ve 14 Gas Pressure Test Nipple Locations 15 Fitting the Remote Control 15 Commissioning 16 Information for Users which must be advised by the installer verbally or in writing 17 Servicing Instructions...

Page 3: ...Technical Data with Eurosit Gas Valve 630 Gas Type System Pressure Main B u r n e r Nozzle Nominal Output Maximum operation Minimum Output Low operation Pilot N o z z l e size Low Operation By Pass He...

Page 4: ...ack Satin Black Enamel Bottle Green Enamel Blue Enamel Decorative Plinth Optional Extra Technical Data with Mertik Maxitrol GV34 Gas Valve 5 6 2 1 3 4 PILOT OFF I G N ON Gas Gas Pressure mbar Main Jet...

Page 5: ...251 1987 Fireplace Components BS 1289 PT 1 1986 Flue Block Systems BS 5440 PT 1 2000 Flues BS 5440 PT 2 1989 Ventilation BS 5871 PT 1 1991 Installation of Gas Fires BS 5482 PT 1 1994 LPG Installations...

Page 6: ...ce seek expert advice Installation of the Gas Supply BS 6891 NOTE Ensure that the gas supply is capable of delivering the required amount of gas and is in accordance with the relevant current standard...

Page 7: ...o section 3 to determine which ue systems are suitable for your stove size having selected a suitable ue system please follow the applicable installation method 7 1 Installation to a ue pipe system IM...

Page 8: ...er uous detailing for comparatively small costs and the result will be a pleasure for many years The measurements are for advice only In all installations surrounding in ammable materials must not exc...

Page 9: ...ppliance b Connect a suitable gas pressure gauge to the test nipple turn the gas supply on and check that the gas connections are sound If satisfactory light the appliance Check all the gas connection...

Page 10: ...her than those supplied with the appliance The coal effect is very fragile under no circumstances should force be used to locate the effect Damage to the coal effect is not covered by warranty Correct...

Page 11: ...park ensure battery is tted Ensure control knob is in the off position Push in the control knob and turn to the pilot position keeping the knob depressed Press the ignition button The pilot should now...

Page 12: ...ve 630 with Manual Override Removing Gas valve Cover Plate 6 4 2 Remove screw and gently remove cover Supply pressure test nipple Operating pressure test nipple Operating pressure adjustment 6 4 2 Fro...

Page 13: ...for 30 seconds if the pilot has lit if it has not lit then repeat the pilot lighting procedure to maximum of 6 attempts If after 6 attempts the pilot has not ignited leave the appliance for 2 minutes...

Page 14: ...of the front cover next to the on off knob push outwards and lift the cover off Pilot flame adjustment screw preset at factory Operating pressure adjustment screw The direction is indicated on the bra...

Page 15: ...ver b 2x small single wire connectors Fit to the micro switch c 2x larger connectors t to the motor Note these two connectors are different in size and t only to the appropriate sized connector on the...

Page 16: ...cuit switching off the gas to the pilot assembly The TTB acts as a ue spillage detector This detector responds very quickly to ue spillage with in 1 2 minutes Note If there are any extractor fans in t...

Page 17: ...12 months c Servicing and spare parts can be obtained by contacting the stockist from which the stove was purchased d The stove s paint may smell for at least 3 4 hours as it cures It is advisable to...

Page 18: ...de the stove paying particular attention to the burner ports e Carry out any remedial work as a result of the functional checks f Inspect all the ceramic parts and replace any which are broken or badl...

Page 19: ...UROHEAT DISTRIBUTORS H B S LTD Aug 2006 Instructions Part number IN1016 Ed G 19 Note locating lug PUSH Reassembly 4mm Hexagon key Pilot jet removal and replacement Dismantling LOCATE OPRN SLIGHTLY LIF...

Page 20: ...ear of the stove Lift side panel outwards at the bottom and remove Remove thermocouple from pilot assembly Removing Thermocouple and Pilot Assembly Caution Side panel coating can be easily damaged Acc...

Page 21: ...el Loosen rear heat shield screws Gently slide backwards the rear heat shield 15mm Lift bottom of side panel upwards Pull the side panel towards the rear of the stove Lift side panel outwards at the b...

Page 22: ...e used See appliance data b The pilot nozzle must be changed to the required nozzle for the gas type to be used c Eurosit 630 gas valve the low re bypass nozzle in the gas control valve must be change...

Page 23: ...y the wrong tting i e With a long thread it will cause the valve not to work properly The symptoms of this are that the manual over ride will not work and you may nd that the tting leaks If it is in t...

Page 24: ...Code Telephone Number Year 3 Annual Service Completed Date ___________ Parts Replaced Service Engineer House Name Number Street Name Locality Name Post Town County Post Code Telephone Number Year 4 A...

Reviews: