background image

(Only for double-insulated, cord-connected appliances):

SERVICING OF DOUBLE-INSULATED 

APPLIANCES

A double insulated appliance is marked with one of the 
following: The words “DOUBLE INSULATION” or “DOUBLE 
INSULATED” or the double insulation symbol (square within a 
square).

In a double-insulated appliance, two systems of insulation 
are provided instead of grounding. No grounding means is 
provided on a double-insulated appliance, nor should a means 
for grounding be added to the appliance. Servicing a double-
insulated appliance requires extreme care and knowledge of 
the system, and should be done by qualified service personnel. 
Replacement parts for a double-insulated appliance must be 
identical to the parts they replace.

WARNING!

 

Only motorized nozzle is double insulated. To reduce risk 
of electrick shock - connect vacuum cleaner to a properly 
grounded outlet.

IMPORTANT WARNINGS

1.  This machine is also suitable for commercial use, for  

 

 

example in hotels, schools, hospitals, factories, shops and  

 

offices and for normal housekeeping purposes.

2.  This machine is not suitable for picking up health  

 

 

endangering dust, unless all special authorised   

 

 

local/state federal precautions are complied with.

3.  This machine is for dry use only and shall not be  

 

 

used or stored outdoors in wet conditions. Store indoors   

 

between max. 60°C (degrees centigrade) and min. 0°C    

 (degrees 

centigrade) 

140°Fahren 

heit / 32°Fahrenheit..

4.  The machine must not be used for the suction of water    
 or 

other 

liquids.

5.  Live conductors must not be vacuum cleaned by the  

 

 

machine for dry dust before their current has been 

 

switched off. This is to avoid creating a short-curcuit  

 

 

through the dust remaining in the nozzles and tubes.

6.  The machine must not be used for picking up combustible  
 

or explosive materials, nor should it be used in an  

 

 explosive 

atmosphere.

7.  Under no circumstances should the machine be used for  
 

picking up hot material. In particular the machine must not  

 

be used for cleaning open and closed fireplaces, ovens    

 

or similar objects that contain warm or glowing ashes.

8.  The machine must not be used if the electrical cord or             
            plug  shows  any  sign  of  damage.  Regularly  inspect  the                        
 

cord and plug for damage, in particular if it has been  

 

 

crushed, shut in a door or run over.

9.  The machine must not be used if it is faulty.
10.  Do not unplug by pulling on cord. To unplug, grasp the    
 

plug, not the cord.

11.  Always turn off this vacuum cleaner before connecting or  
 

disconnecting motorized nozzle.

12.  When repairing or replacing the cord, the same type of    
      cord as originally supplied with the machine must be  

 

 

used. This cord can be supplied by the manufacturer.

12b.If the fixed supply cord is damaged, it must be replaced   
 

by the manufacturer or its service agent or a similarly  

 

 

qualified person in order to avoid a hazard.

13.  The plug must always be removed from the socket outlet  
 

before starting any maintenance of the machine or the    

 cord.
14.  Disconnect vacuum cleaner before servicing and when not  
 

in use. Do not leave unattended vacuum cleaner 

 plugged 

in.

15.  No changes or modifications to the mechanical or  

 

 

electrical safety devices should be made.

INSTRUCTIONS FOR USE

Before using the vacuum cleaner make sure that the voltage 
shown on the rating plate on the vacuum cleaner corresponds 
with the main voltage. 

Accessories shown in the illustrations may vary from model to 
model.

MAINTENANCE

Always keep the vacuum cleaner in a dry place. The cleaner 
is designed for continuous heavy work. Depending on the 
number of running hours – the dust filters should be replaced. 
The dust bag must be replaced at the same time the Main-
filter (sack-filter) is replaced/cleaned. Keep the container clean 
with a dry cloth, and a small amount of spray polish. 

Any 

other servicing should be performed by an authorized 
service representative.

Do not use with damaged cord or plug. If appliance is not 
working as it should, has been dropped, damaged, left 
outdoors or dropped into water, return it to a service center.

While the machine is in use do not pull or carry by the 
cord, use cord as a handle, close a door on cord, or pull 
cord around sharp edges or corners.  Keep cord away 
from heated surfaces.

The size and quality of the dust bag and fi lters affect the 
machine effi ciency. Use of non original dust bags or non 
original fi lters can cause restricted air fl ow which may lead to 
machine overload. 

This machine is equipped with a thermal cut-out to protect 
the motor and other vital machine parts from overheating. 
Should the machine cut out, you will have to wait at least 5-
10 minutes for it to automatically reset. While you are waiting, 
switch the machine off and unplug it, then check the hose, 
dust bag and filters to be sure that nothing is blocking the flow 
of air through the machine.

When cleaning is performed roll up the extension cord 
starting at the machine end and store it at the machine 
belt by snapping the nylon tie around the cord.

15

823 0100 050 Instruction for use Euroclean Back Vac 6 Back Vac 10.indd   15

823 0100 050 Instruction for use Euroclean Back Vac 6 Back Vac 10.indd   15

2008-02-25   14:39:25

2008-02-25   14:39:25

Summary of Contents for Back Vac 10

Page 1: ...INSTRUCTIONS FOR USE MODE D EMPLOI INSTRUCCIONES DE USE Back Vac 6 Back Vac 10 823 0100 050 Edition P00 2008 02 Printed in China READ THIS BOOK LEA ESTE LIBRO LISEZ CE MANUEL...

Page 2: ...2 Contents Contenido Table des mati res 2 16 English 2 12 17 19 Fran ais 2 12 20 22 Espanol 23 Data READ THIS BOOK LEA ESTE LIBRO LISEZ CE MANUEL...

Page 3: ...d this book prior to operating or attempting any service or maintenance procedure to your machine could result in injury to you or to other personnel damage to the machine or to other property could o...

Page 4: ...5 1 5 2 5 3 ADJUSTMENT 3 1 4 ADJUSTMENT 1 4...

Page 5: ...2 1 2 HOSE CONNECTION 4 1 4 2 2 2 5 3 5 4 4 3 5 5 5...

Page 6: ...6 5 6 5 7 5 8 6 3 6 2 6 1 8 1 8 CORD RELIEF 8 2...

Page 7: ...7 5 10 5 9 6 9 ON OFF 7 1 7 2 On Off 9 1 OPERATION 7 CORD SET...

Page 8: ...8 10 2 12 HEPA FILTER 12 1 12 2 11 MAIN FILTER 11 1 2 2 1 1 10 DUST BAG 10 1 11 2...

Page 9: ...9 12 3 1 1 2 2 12 4 10 3 10 4 10 5 11 3 1 1 2 2 12 5 11 4 11 5...

Page 10: ...14 1 14 2 13 PRE FILTER 13 2 13 1 14 EXHAUST FILTER 10 15 POWER NOZZLE 15 1 15 2...

Page 11: ...14 3 13 3 13 4 14 5 13 5 14 4 11 15 3...

Page 12: ...12 16 16 2 17 20 18 18 2 18 3 19 19 2 19 3 20 2...

Page 13: ...ad this book prior to operating or attempting any service or maintenance procedure to your machine could result in injury to you or to other personnel damage to the machine or to other property could...

Page 14: ...door or on wet surfaces Connect to a proper grounded outlet only See grounding instructions Do not allow to be used as a toy Close attention is necessary when used by or near children Use only as desc...

Page 15: ...plug not the cord 11 Always turn off this vacuum cleaner before connecting or disconnecting motorized nozzle 12 When repairing or replacing the cord the same type of cord as originally supplied with t...

Page 16: ...dust rubbish from being released In that case peel off the protective paper and fold the cardboard collar to seal the bag 11 Main filter When you replace the dustbag also replace or clean the Main fil...

Page 17: ...e des cigarettes Cette machine n est pas appropri e la s lection vers le haut de la sant mettant en danger la poussi re moins que toutes les pr cautions f d rales autoris es sp ciales d tat local soie...

Page 18: ...ux 10 Ne pas d brancher le cable lectrique en tirant sur le c ble mais en enlevant la fiche de raccordement 11 Veuillez toujours d brancher votre appareil avant de raccorder ou d enlever l lectrobross...

Page 19: ...ertains sacs poussi re peuvent tre scell s pour emp cher la poussi re les d chets de s chapper Dans ce cas retirer le film de protection Replier le carton et sceller le sac 11 Filtre du sac Profiter d...

Page 20: ...usar Esta aspiradora est dise ada para ser segura cuando es utilizada para funciones de limpieza tal como se especi can En caso de que las partes el ctricas o mec nicas se da en la aspiradora y o los...

Page 21: ...ado un medio de puesta a tierra al artefacto El servicio de un artefacto de doble aislaci n requiere extremo cuidado y debe ser realizado solamente por personal de servicio cali cado Las partes de ree...

Page 22: ...gue el cart n y selle la bolsa 11 Filtro de la bolsa Cuando cambie la bolsa del polvo puede ser buena idea cambiar o limpiar el filtro de la bolsa Esto puede hacerse una vez haya sacado la bolsa del p...

Page 23: ...erlift max inches H2O 99 99 Air ow max cfm 144 144 Filter Area main lter Sq in 217 311 Main Filter Filter Ef ciency DIN 44956 2 98 2 98 2 Dust bag capacity Gallon 1 0 1 8 Tank Capacity Gallon 1 5 2 6...

Page 24: ...24...

Reviews: