Eurocave INOA25 Operating And Installation Instructions Download Page 9

4

GB

7 - I

NSTALLING THE CONDITIONER

I - General points

- Never damage the appliance’s refrigerating circuit.

Your conditioner’s power lead is supplied without a plug. “Fitting a power plug or connecting the conditioner to a junction box must be carried out by a

In all cases, connection of your conditioner must be carried out on an earthed socket to prevent any risk of electric shock.

*not valid for some countries

IMPORTANT :

any electrical work must be carried out by a 

 electrician. Power outlet not valid for some countries.

Electric  connection  must  be  carried  out  by  means  of  a  device  to  ensure  isolation  from  the  mains  system. The

isolating device should open all of the contacts of all the poles ensuring complete disconnection in line with 

the conditions

 

 

 

  r

 

 

 

 

in  over-voltage category  III. Installation  must be ca ried out in  compliance with national

 

installation regulations.

 Positioning your conditioner:

The conditioner produces cold air inside the cellar and expels hot air outside (see diagram A).

- Do not install the conditioner facing the door of the room (risk of condensation on the door joints).

- Do not place the external section of the conditioner above a source of heat.

- For insulation reasons, there must be no windows or bay windows in the room to be conditioned.

- Is it not better to state that pipes with hot water must be insulated so that there is no heat loss?

- The exterior of the conditioner must not be located in an area subject to ingress of rain, wind, snow or poor 

  quality air.

- No heat-producing appliance must be located in the area to be conditioned (e.g. refrigerator, radiator, boiler).

- Do not obstruct the air entry and exit points.

- Never place a container or object containing liquid on top of the conditioner.

- The room where the hot air is expelled must, ideally, be approximately twice as large as the wine cellar and well

ventilated so that the hot air can be properly expelled.

Wait 48 h 

- Never connect several conditioners to a multi-socket.

 Recommendations:

- Fit your conditioner as close as possible to the ceiling in order to ensure uniform dispersal of cold air in the

cellar.

- We recommend that you leave a space of 200 mm between the ceiling and conditioner housing to make it easier

- Air outlets (hot and cold) must not be obstructed by any obstacles (minimum distance: 1500 mm).

Direct the cold air outlet so it is facing the bottles (see diagram D).

 Installation:

(see B diagrams)

The conditioner was designed to be completely modular and adapt to any type of cellar.

however, installing it at a height for improved air convection).

You also have the option of expelling hot air outside the room by way of extractor piping (standard piping, 160 mm in diameter, not supplied).

Ventilated

room

Temperature:

Max.: 35°C

Min.: -5°C

CELLAR

Diagram A

Bottles

Door

Door

Conditioner

Conditioner

CELLAR

CELLAR

Diagram D

Hot air

expelled

Cold air

discharged

Cold air

discharged

Conditioner housed inside the cellar

with extraction facing forwards /

aesthetic front panel on the outside

Conditioner housed outside the cellar

with extraction facing forwards /

aesthetic front panel on the inside

Conditioner housed outside the cellar

with extraction on the left side /

aesthetic front panel on the inside.

Conditioner housed inside the cellar,

Diagram B

Diagram B

Diagram B

Diagram B

Bottles

Door

Conditioner

CELLAR

Bottles

Hot air

expelled

9

Summary of Contents for INOA25

Page 1: ...Operating and installation instructions INOA cellar conditioners March 2009 1 ...

Page 2: ...scription II Installing the remote control inside the cellar III Installing the remote control outside the cellar 10 COMMISSIONING YOUR CONDITIONER I Connection II Switching on III Remote control description IV Installing the remote control V Setting the temperature VI Silent function VII Heating function VIII Changing the remote control batteries IX Discharging condensate 11 MAINTENANCE 12 OPERAT...

Page 3: ... CABINETS STORAGE SYSTEMS CELLAR CONDITIONERS SYSTEM TO SERVE W INES BY THE GLASS Origine Classic Compact Leather Meuble àVins Elite Modulothèque Modulocube Modulorack Inoa Vin auVerre Sommelier Product not available in certain countries 3 ...

Page 4: ...ible oxidation of its tannins For this reason we strongly advise that wines be stored in the dark far from U V light Protection from vibration Vibration disturbs the slow process of your wine s biochemical evolution and is often fatal for the finest wines The housingof your EuroCave conditioner is fully sound proofed by 20 mm polyethylene foam and the compressor and fans are fitted with silent blo...

Page 5: ... Mounting frame conditioner seal 9 Evaporator to be cleaned regularly 10 Condenser to be cleaned regularly 11 Inside of cellar 12 Remote control 13 Grid securing screws quantity 24 14 Aesthetic front panel securing screws quantity 4 15 Screws to fix frame to the wall quantity 4 16 Screws to fix conditioner to the frame quantity 4 1 CONDITIONER DESCRIPTION HOTAIR COLDAIR 5 ...

Page 6: ... Take a firm hold on the plug and pull out smoothly in a straight line from the wall socket If the power lead is damaged it must be replaced by a qualified electrician Do not allow children to climb sit stand on or hang from the conditioner They could damage the conditioner as well as badly hurting themselves Never damage your appliance s refrigeration unit W hen using your conditioner you should ...

Page 7: ...ar conditioner is to climate control any kind of fully insulated room creating an ideal wine cellar environment by monitoring and adjusting the temperature and humidity TEC HNOLO GY The conditioner s housing is dampened against sound and the compressor and fans are fitted with silent blocks to absorb any residual vibration A quiet conditioner the system automatically adjusts speeds to ambient tempe...

Page 8: ...nce m2 C W It determines the material s ability to conduct heat R e λ The greater the R coefficient the better the insulation λ thermal conductivity coefficient There are 3 types of insulation boards Insulator only complex with plaster cover or sandwich plaster both sides Depending on the type of insulator chosen several methods of fitting are possible Against the walls Standard extruded polystyre...

Page 9: ...d e g refrigerator radiator boiler Do not obstruct the air entry and exit points Never place a container or object containing liquid on top of the conditioner The room where the hot air is expelled must ideally be approximately twice as large as the wine cellar and well ventilated so that the hot air can be properly expelled Wait 48 h Never connect several conditioners to a multi socket Recommenda...

Page 10: ... mm min and 280 mm max III Fitting Fold the ring s 4 supports inwards 1 Fit the 2 extendable ducts onto the rings of the metallic frame 2 Screw the securing rings onto the ducts 3 Position the metallic frame while passing the flexible ducts through the 2 holes drilled into the wall 4 Push back the 4 supports towards the outside of the ring 5 Screw the metallic frame onto the wall with 2 high screw...

Page 11: ...Wall mounting bracket dimensions Cold side Inoa located outside the cellar Hot side Inoa located inside the cellar ...

Page 12: ...All DATE OF PRODUCTION Since June 2007 Position of the panels Maximum pipe lengths recommended Two parts 7 linear meters of pipe diameter 160 mm without elbow Or Two parts 5 linear meters of pipe diameter 160 mm with 3 90 s elbows Cold air outlet front side Warm air side Cold air side Cellar air in Cold air out You can only duct the warm air side Do not duct cold air ...

Page 13: ...e cellar 25 m3 50 m3 Cooling power 600 W 1200 W Maximum distance for the remote control 10 m 10 m Quantity of speeds for the condenser fan 4 4 Quantity of speeds of the evaporator fan 3 3 Condenser fan air flow per speed 1 2 3 4 in m3 h 230 335 431 563 273 353 473 682 Evaporator fan air flow per speed 1 2 3 in m3 h 199 285 382 227 352 445 Gas load in R134a 400 grs 400 grs Pressures BP and HP for 3...

Page 14: ...ess firmly onto the foam 18 Screw down the conditioner housing using 2 screws at the top those retained earlier and 2 screws at the bottom supplied in the accessories packet 19 Fitting onto a door You can fit the conditioner onto a door In this case it is ESSENTIAL to check that the door is capable of supporting a weight of 46 kg and that it does not produce vib ration The procedure for fitting is...

Page 15: ...od you must not use the flexible ducting supplied with the conditioner Fit the reducer directly onto the mounting frame through the wall 1 Position the air extraction piping standard piping 160 mm in diameter not supplied 2 3 For this type of fitting it is necessary to ensure sealing around the piping Consult your EuroCave distributor IV Discharging condensate The conditioner was designed to allow...

Page 16: ...itioner is fitted with a refrigerating unit an evaporator forces cold air inside the room a condenser expels the hot air outside 14 The evaporator fan operates continuously to ensure that air is constantly mixed and that temperatures are as uniform as possible in accordance with speeds automatically adjusted according to requirements ...

Page 17: ...t you place the remote control as close as possible to the bottles Fit the unit close to your bottles using the supplied pegs and screws see diagram below NB Do not place the remote control in the path of the conditioner s cold air flow Temperature indicator Low battery indicator Knob 9 INSTALLING THE REMOTE CONTROL Temperature units according to the country Confirmation and on off key Temperature...

Page 18: ...iver see diagram below Remove the central knob unscrew the screw with a small screwdriver and open the unit see diagram below On the back connect the sensor s 2 wires blue and red to the circuit connector using a small flat screwdriver see diagram be low You can connect either the blue wire or the red wire to the circuit connector Pass the wires through the recess on the top of the unit Close the ...

Page 19: ...he pictogram appears Press The screen appears Press The pictogram appears Press appears Press The pictogram appears Press The screen appears then If you wish to reprogramme the remote control for an internal sensor disconnect the wired sensor and reprogramme the remote control in internal mode IN by repeating the first two steps described in the paragraph above see 5 III b p 11 The 2nd screen disp...

Page 20: ...e key on your remote control for about 8 seconds until the indicator goes off To put your conditioner on standby press and hold down the key on your remote control for about 5 seconds and release it before the indicator goes off III Remote control description Radio frequency remote control 433 92 Mhz Each remote control has a personalised code matched to the conditioner Temperature indicator Low b...

Page 21: ... retailer V Setting the temperature Setting the temperature of your conditioner is carried out entirely from the remote control which has the following layout Temperature display displays the actual temperature inside your cellar Setting keys allow you to select the desired temperature inside the cellar To adjust the temperature Press then immediately release the key The setting then appears the t...

Page 22: ...on The EuroCave INOA conditioner has a heater 650 W allowing the internal temperature in your cellar to be maintained at an optimal level As soon as the temperature drops below the programmed temperature the heating function is automatically activated VIII Changing the remote control batteries Remote control power supply 1 x 3V CR 2430 battery 2 batteries supplied Battery life 2 years approx The r...

Page 23: ... displayed As soon as the green LED on the board stops flashing end of synchronising mode the conditioner and remote control are then synchronised Exit RF mode by pressing the key on the remote control 1 2 3 On off button Green LED 11 MAINTENANCE It is necessary to thoroughly clean the conditioner s internal elements every year Unplug the appliance Place the appliance on the ground to disassemble ...

Page 24: ... any specific purpose other than that for which it was des igned EuroCave cannot be held responsible for any errors in this manual nor for any damage linked to or following the provision performance or use of the equipment item All photocopying reproduction translation wether partial or total are strictly prohibited without prior written consent from Eu roCave 22 ...

Page 25: ...www eurocave co uk info eurocave co uk EuroCave UK 57 Chiltern Street London W1U 6ND 020 7935 4679 info eurocave co uk 23 ...