18
WARNING:
Always use the safety strap when drilling vertically and/or up-side-down. The
safety strap does not replace the magnetic force of the magnetic drilling machine: it is simply
used to secure against falling in the event of a magnet malfunction.
3.2 Prior to use
Please make sure that the contacting surface for the magnet is level, clean and rust free.
Remove any varnish or primer. When working on materials that are not magnetisable, suitable
fixation devices, obtainable as accessories from EUROBOOR, e. g. suction plate, vacuum plate or
pipe-drilling machine must be used.
When working on steel materials with a material thickness of less than 6 mm, the workpiece must
be reinforced with an additional steel plate in order to guarantee the magnetic holding power.
Check the machine for possible damage; Before using the machine, you must carefully check the
protective components or slightly damaged components to ensure they are operating perfectly and
as intended.
Check that moving parts are in perfect working order, do not jam and check whether the parts are
damaged. All parts must be correctly installed and fulfill all conditions necessary to ensure perfect
operation of the machine.
Damaged protective components must be repaired or replaced according to specifications by
EUROBOOR or any authorised EUROBOOR dealer.
DO NOT
use under wet conditions or in presence of flammable liquids or gases.
DO NOT
let children come into contact with the machine. Supervision is required when
inexperienced operators use this machine.
Electrical safety
The electric motor has been designed for one voltage only. Always check that the power supply
corresponds to the voltage on the rating plate.
Your EUROBOOR magnetic drilling machine is designed in class I (grounded) according to EN 61029-1.
Earth wire is required.
If the power cable is damaged, it must be replaced by a specially prepared cable available at
EUROBOOR or your EUROBOOR dealer.
Extension cable
If an extension cable is required, use an approved 3-core extension cable suitable for the power input
of this machine (see technical data).The minimum conductor size is 1.5 mm²; the maximum length is
30 meter. When using a cable reel, always unwind the cable completely.