background image

ISSUE 1/Original version/OCT 2013 

 
Symbol 

Term, meaning 

Explanation 

 

 
Read documentation 

Be absolutely sure to read the enclosed 
documentation such as the Instruction Manual and 
the General Safety Instructions. 

 

 
Wear ear protection 

 
Use ear protection during operation. 

 

 
Wear eye protection 

 
Use eye-protection during operation. 

 

 
Danger/warning/caution 

 
Observe the information in the adjacent text! 

 

 
European conformity symbol 

 
Confirms the conformity of the power tool with 
the directives of the European Community. 

 

 
Class of protection I 

Product with basic insulation and exposed 
(touchable), conductive parts additionally 
connected to the protective earth conductor. 

 
mm 

 
Millimeter 

 
Unit of measure for length, width, height or depth 

 
kg 

 
Kilogram 

 
Unit of measure for the mass 

 

 
Volt 

 
Unit of measure for the electric voltage 

 

 
Ampere 

 
Unit of measure for the electric current intensity 

 

 
Watt 

 
Unit of measure for the output 

 

 
Newton 

 
Unit of measure for the force 

 
min 

 
Minutes 

 
Unit of measure for the time 
 

 
no 

 
No-load speed 

 
Revolution speed at no-load 

 
1/min 

 
per minute 

 
Unit of measure for number of revolutions, 
strokes, impacts or oscillations per minute. 

 

Summary of Contents for ECO.32

Page 1: ...USER MANUAL ECO 32 Magnetic Drilling Machine SERIAL NO ____________ DATE OF PURCHASE __________ E U R O B O O R FOR PROFESSIONALS BY PROFESSIONALS ...

Page 2: ...ls and products to help you be more productive Before operating your new magnetic drilling machine please read all instructions first These include the Operator s Manual and Warning Label on the unit itself With proper use care and maintenance your model will provide you with years of effective hole drilling performance TO REDUCE THE RISK OF INJURY USER MUST READ AND UNDERSTAND ALL INSTRUCTIONS EUR...

Page 3: ...ISSUE 1 Original version OCT 2013 3 Fig 1 ...

Page 4: ...he directives of the European Community Class of protection I Product with basic insulation and exposed touchable conductive parts additionally connected to the protective earth conductor mm Millimeter Unit of measure for length width height or depth kg Kilogram Unit of measure for the mass V Volt Unit of measure for the electric voltage A Ampere Unit of measure for the electric current intensity ...

Page 5: ...ugs 2 Avoid body contact with grounded surfaces such as pipes radiators ranges and refrigerators There is an increased risk of electric shock if your body is grounded 3 Do not expose magnetic drilling machines to rain or wet conditions Water entering a machine will increase the risk of electric shock 4 Do not abuse the cord Never use the cord to carry the magnetic drilling machine or pull the plug...

Page 6: ...itch does not turn it on or off Any tool that cannot be controlled with the switch is dangerous and must be repaired 5 Disconnect the plug from the power source before making any adjustments changing accessories or storing the tool Such preventive safety measures reduce the risk of starting the tool accidentally 6 Store idle Magnetic drilling machines out of reach of children and other untrained p...

Page 7: ...nto the work piece before drilling Do not perform any design assembly or construction activities on the work piece while the machine is turned on Before turning on the machine make sure the accessory has been mounted correctly Always use the recommended speed for the accessories and the material Do not use the machine on the same work piece on which electric welders are being used Use only an appr...

Page 8: ...e the year and month of manufacturing and identification number is engraved on the frame magnet and the motor unit Example 032 12 11 001 Model type Year of Manufacture Month of manufacture Identification number Package Contents 1 Magnetic drilling machine 1 Carrying case 1 Drill guard 3 Handles 1 Allen Key 2 5 1 Allen Key 4 1 Allen Key 5 1 Wrench 1 Lubrication system 1 Safety chain 1 Cutting oil 1...

Page 9: ...fications as per ISO 4871 Sound emission Measured A weighted sound power level LwA re 1 pW in decibels 95 Measuring uncertainty KwA in decibels 3 A weighted emission pressure power level measured at the workplace LpA re 20 μPa in decibels 84 Measuring uncertainty KpA in decibels 3 Vibration emission Rated acceleration in m s 0 5 Measuring uncertainty K in m s 1 5 REMARK The sum of the measured emi...

Page 10: ...nforced with an additional steel plate in order to guarantee the magnetic holding power Check the machine for possible damage Before using the machine you must carefully check protective devices or slightly damaged components to ensure they are operating perfectly and as intended Check that moving are in perfect working order and do not jam and check whether parts are damaged All parts must be cor...

Page 11: ...ARD FIG 1 The guard protecting against chippings and accidental contact must always be mounted during operation 1 Hold the guard in front of the magnet aligning the slots in the guard with the holes in the magnet 2 Fit the screws into the hole located in the side of the magnet WARNING Always use the Safety guard FITTING THE LUBRICATION SYSTEM FIG 1 The lubrication system can be used for horizontal...

Page 12: ...l the magnet is placed on Paint or coating of the material the magnet is placed on Metal chips oil or other dirt under the magnet If the LED indicator see page 13 lights up GREEN the magnet is generating sufficient attachment force If the LED indicator lights up RED the magnet may not generating sufficient attachment force WARNING Do not use this machine when LED indicator is RED magnet is may not...

Page 13: ...d on following the procedure as described below ACTIVATING THE MAGNET Connect the machine to the mains work piece To activate the magnet press the red button Fig 2 3 The switch will be lit red The LED indicator Fig 2 2 will be lit GREEN if generated magnetic force is sufficient When LED indicator turns RED there is not enough magnetic force and it is not safe to work To deactivate the magnet press...

Page 14: ...egularly refill the holes of the spindle and continue drilling 8 Apply less pressure when the drill cuts through the material 9 Turn the arms to put the motor in highest position and turn off the motor unit 10 Remove the burr metal chips and clean the cutter and surface without getting injuries Caution The metal piece drilled out can be sharp and very hot DRILLING WITH ANNULAR CUTTERS Annular cutt...

Page 15: ...e 5 self locking set screws at the left side Tighten screws in series until the gear rack moves freely in the dove tail guide but does not allow the motor to wobble Cleaning WARNING Blow dirt and dust out of the main housing with dry air as often as dirt is seen collecting in and around the air vents Wear approved eye protection and approved dust mask when performing this procedure WARNING Never u...

Page 16: ...achines operation must be checked to ensure that all components are working correctly Replace any defective parts immediately This prevents properly function parts from being damaged CARBON BRUSHES Brushes should be checked to make sure there is no abnormal wear present This should be checked at least once a week if used frequently If the carbon brush has worn more than 2 3 the original length the...

Page 17: ...justing all setting nuts and screws 3 Operate the slide up and down a few times to test the movement and make any further necessary adjustments Try to ensure that all the screws are exerting a uniform pressure on the slide from top to bottom A perfectly adjusted slide will operate freely up and down without any sideways movement REPAIR MODIFICATION AND INSPECTION Repair modification and inspection...

Page 18: ... guide not mounted straight Dirt between spindle and triangular guide Motor starts running when magnet switch is turned on Damage or defective relais in control unit Motor making a rattling sound Gear ring bottom of the armature worn out Gear s worn out No grease in gear box Motor humming big sparks and motor has no force Armature damaged burned Field burned Carbon brushes worn out Motor does not ...

Page 19: ...there is machine failure and the problem cannot be saved with one of the above solutions PROTECTING THE ENVIRONMENT Separate collection This product must not be disposed of with normal household waste Should you find one day that your EUROBOOR product needs replacement or if it is of no further use to you do not dispose of it with household waste Make this product available for separate collection...

Page 20: ...oupling nut main cable 29 020 0036 Main Cable 30 020 0182 Screw washer nut 31 PP RSEU Rear plate 32 020 0101 Panel screw 33 PP 32EU Front plate 34 020 0206 Sensor LED cable 35 020 0006 On Off switch 36 020 0016 Fuse Holder 37 020 0017 Fuse F2A 38 020 0011 Magnet Switch 39 020 0001 Control Unit 220v 020 0002 Control Unit 110v 40 020 0037 Cable clamp 41 032 0101 Motor unit 220v 032 0102 Motor unit 1...

Page 21: ...ISSUE 1 Original version OCT 2013 21 EXPLODED DRAWING of ECO 32 ...

Page 22: ...ISSUE 1 Original version OCT 2013 22 ...

Page 23: ...agnetic Drilling Machine Type ECO 32 Ratings and principal 230 240V 50Hz Class I Characteristics ECO 32 1000W N0 775 minˉ Applicable EC Directives Machinery Directive 2006 42 EC Relevant standard s EN 55014 1 2006 A1 2009 A2 2011 Specification s Directive s EN 55014 2 1997 A1 2001 A2 2008 EN 61000 3 2 2006 A2 2009 A2 2009 EN 61000 3 3 2008 EN 61000 3 11 2000 EN 61029 1 2009 A11 2010 EN ISO 12100 2...